CLICK 516 • USER GUIDE
10
Navigating the Menu Via the Push-Button
You navigate through the menu using the push-button:
˽
Hold – Pressing and then holding for at least 1½ seconds allows you to enter the Click
516 mode selection process.
˽
Press – Pressing and then quickly releasing the push-button allows you to make a
selection in the menu.
The menu is used to select and run an application's operating modes. Select a mode by
navigating through the main menu (multicolored LEDs) and the submenus (yellow and red
LEDs) as described below:
1
Enter the main menu by holding the push-button down. Continue holding the push-
button to cycle through the entire menu.
2
Release the push-button once the cycle reaches the desired mode (see Table ).
3
Press the push-button again to select the mode. Once the mode is selected it will start
running. If you selected to reset the device, the submenu of yellow LEDs will start (the
first LED will light up).
4
Hold the push-button to cycle through the options of the submenu.
5
Release the push-button once the desired option is displayed.
6
Press the push-button again to select the option. The mode will now start running.
Run Mode (blue solid)
Run mode is the first mode presented in the mode selection process, but usually the second
one to be used. It might first be necessary (at least the first time the device is used) to use
Device Setup mode. When the device is in Device Setup mode, Click Supervisor can be
used to configure the device (see the Device Setup Mode section below). Once that is com-
pleted, use the push-button to select Run mode (blue solid).
While in Run mode, the Click 516 operates in two (2) states:

Normal State

In normal state, the Click 516 polls Event Data Messages from a SmartSensor HD and veri-
fies that the duration field in the message is less than 1.9 seconds. If it is found to be longer
than 1.9 seconds the duration is changed to be 1.9 seconds. The Event Data Message is con-
verted to a Contact Closure Message and passed onto a Click Contact Closure Card using
the Z4 Protocol. In normal state the Click 516 also polls Interval Data from a SmartSensor
HD and checks for the following:
The Speed and Occupancy for each lane is tested to determine if the Speed is below the
Speed Threshold and the Occupancy is above the Occupancy Threshold. If this condition
is true, the Click 516 enters HIOCC state; if this condition is false, the Click 516 stays in
NORMAL state.