List Of Rs-232C Commands - Pioneer PDP-R05E Service Manual

Media receiver
Table of Contents

Advertisement

1

6.8 LIST OF RS-232C COMMANDS

RS-232C commands can be used in Service Factory mode.
Before using RS-232C commands, it is necessary to change the factory presetting. See "6.3. USING RS-232C COMMANDS."
A
Command
A
ABL
Adjusting power consumption
B
BCP
Transmitting the backup data to the DIGITAL Assy
BAVS00
Setting the power supply for the DTB antenna to 0 V
BAVS02
Setting the power supply for the DTB antenna to 5 V
BSL
Adjusting side mask B
BYG
BY GAIN
C
CHM
Clearing the hour meter
B
CNG
Clearing MR NG information
CPC
Clearing the power-on counter
CPD
Clearing power-down information
CPM
Clearing the pulse meter
CSD
Clearing shutdown information
CTM
Clearing the modification log
D
OSDS01
Turning on the on-screen display
OSDS00
Turning off the on-screen display
DRF
Turning off the power for the drive system
DRN
Turning on the power for the drive system
DW*
Decreasing the adjustment value by *
E
C
EDWS00
Prohibiting writing of EDID data
EDWS01
Permitting writing of EDID data
F
F50
Video 50-Hz sequence
F60
Video 60-Hz sequence
F61
PC 60-Hz sequence
F70
PC 70-Hz sequence
F72
Video 72-Hz sequence
F75
Video 75-Hz sequence
FAJ
Determining the adjustment values for the unit
FAY
Turning Service Factory mode on
FAN
Turning Service Factory mode off
FCSS00
Focus OFF
FCSS01
Focus ON
D
FST
Final set up
G
GA2
Obtaining the various adjustment values (Add Vrn to GAJ)
GAJ
Obtaining the adjustment values for the panel
GDI
Command to obtain Status
GMM
Switching the gamma levels
GNG
Obtaining NG data of the MR
GNM
Obtaining the serial No. of the MR
GNP
Obtaining the serial No. of the panel
GPC
Obtaining the P ON COUNTER value
GPD
Obtaining power-down information
GPR
Obtaining the PANEL REVISE data
E
GPM
Obtaining the PULSE METER data
GPW
Obtaining the PANEL W/B data
GS1
Obtaining the version data for each device
GS2
Obtaining data on various operations
GS6
Obtaining the any version
GSD
Obtaining shutdown information
GSL
Adjusting side mask G
GYG
GY GAIN
F
156
1
2
Operation
PDP-R05E
2
3
Remarks
PDP-R05XE only
PDP-R05XE only
This command is effective even during Standby mode.
While the OSDSOI command is in force, the duration of on-screen display is unlimited.
On-screen display is prohibited.
*: 1-9, 0 (0 means 10), or F (making the adjustment value the minimum)
The GUI equivalent to that usually displayed when the power is turned on is displayed.
The GET-group commands are effective at any time, including during Standby mode.
Setting value: 000-007
3