2.2.4. Specifications

The table below summarizes all mechanical and environmental specifications.
Electrical and Mechanical Specifications
Enclosure materials
Dimensions
Weight
Input power voltage
Power consumption
Environmental specifications
Altitude rating
IP rating
Humidity
Operating Temperature
range
Storage Temperature range
Shocks
Operating Vibrations
Calibration interval
Anodized Aluminum (6061)
15 x 16.8 x 21.5 cm
4290 g
18 – 32VDC
12W typical
55,000 feet
IP-67
Sealed, no limit
-20 to 60°C – specified range
-40 to 71°C – operating range
-40 to 71°C
6.0g; 20ms half-sine (operational)
40g; 15 ms half-sine (non operational)
4.1g RMS – DO-160F, Cat. SC
None required, maintenance free