WAKING UP BATTERY FROM OVER-DISCHARGE
If the battery is over-discharged this will cause it to drop below its operational voltage and the
BMS will activate, putting the battery into protection mode.
To identify whether your battery is in protection mode you can check the voltage using a
multimeter, if the battery is below 5V then the BMS is in protection mode. In Bluetooth models
the mobile application can be used.
The BLA Marine Performance Lithium Chargers has a wake up function.
If you require support with this product, please contact our Technical Services Teams at
service@bla.com.au in Australia or service@bla.nz.co in New Zealand.

Battery Voltage

BMS Over-discharge
Protection Voltage
SERIES AND PARALLEL OF BATTERIES
There are strict conditions under which the BLA Marine Performance Lithium Batteries Range
can be configured into Series OR Parallel systems. Please note these conditions below.
Not all SNL batteries can be configured into a Series or Parallel system. Please note for all
Bluetooth Batteries. If the battery has Bluetooth they can be paralleled but the BT function
will no longer work. These BT Batteries cannot be configured in Series (eg 2 x 12V to
24V). Series configuration is strictly prohibited.
All BLA Marine Performance Lithium Batteries can be configured into a parallel
configuration up to 4 units in parallel under the conditions outlined in the following pages.
12V
24V
10V
20V
36V
48V
30V
40V

Advertisement