Download Print this page
netta OL12-B015E User Manual

netta OL12-B015E User Manual

Home dehumidifier with r290 refrigerant

Advertisement

Home Dehumidifier
User Manual
OL12-B015E
(With R290 refrigerant)
READ AND SAVE THESE INSTRUCTIONS

Advertisement

loading
Need help?

Need help?

Do you have a question about the OL12-B015E and is the answer not in the manual?

Questions and answers

Chris Parry
February 8, 2025

How do I get CNT on continuous

1 comments:
Mr. Anderson
February 11, 2025

Press the Hum/CNT button on the control panel to select the continuous operating mode on the Netta OL12-B015E.

This answer is automatically generated

Martin Piper
January 31, 2025

Why is the Power light on my machine flashing? And why is the machine making a high-pitched whining noise?

1 comments:
Mr. Anderson
May 14, 2025

The flashing power light and high-pitched whining noise on the Netta OL12-B015E dehumidifier may indicate an operational issue that needs attention. Based on the manual's troubleshooting section and operational guidelines, here are the most likely causes:

### 1. Flashing Power Light
- Water Tank Full: If the Water Full LED (red) is also lit, the water tank is full. The unit will stop operating and the power light may flash to indicate this condition.
Solution: Empty the water tank and reinstall it correctly.

- Improper Power Connection: The unit may not be securely plugged into the wall outlet, or there may be a voltage mismatch.
Solution: Ensure the power cord is firmly inserted and the power source matches the unit’s requirements.

- Temperature Outside Operating Range: The unit operates between 5–35°C. If the room temperature is outside this range, the unit may not function properly and the power light may flash.
Solution: Check that the room temperature is within the allowed range.

### 2. High-Pitched Whining Noise
- Blocked Air Duct or Dirty Filter: An obstructed air duct or dirty filter can cause strain on the fan motor, which may produce a high-pitched noise.
Solution: Inspect and clean the air filter; ensure the air duct is clear of obstructions.

- Fan or Motor Malfunction: A whining noise could also indicate an internal mechanical issue such as a failing motor or fan bearing.
Solution: If cleaning doesn’t resolve the noise, the unit may require professional inspection or servicing.

Would you like help checking the filter or finding a repair service?

This answer is automatically generated

Summary of Contents for netta OL12-B015E

  • Page 1 Home Dehumidifier User Manual OL12-B015E (With R290 refrigerant) READ AND SAVE THESE INSTRUCTIONS...
  • Page 3: Table Of Contents

    Contents BEFORE YOU BEGIN.........1-2 FOR YOUR SAFETY........3-6 INSTANNATION........7-8 PRODUCT OVERVIEW......9-10 OPERATION..........11-15 MAINTANCE.........16-17 TROUBLESHOOTING......18-19...
  • Page 4: Before You Begin

    1. BEFORE YOU BEGIN 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity. The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
  • Page 5 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY  This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.  This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6: For Your Safety

    2. FOR YOUR SAFETY Your safety is the most important thing we concerned! Please read this manual carefully and fully understand before operating your dehumidifier. WARNING OPERATIONALPRECAUTIONS WARNING- to reduce the risk of fire, electric shock or injury to persons or property: ...
  • Page 7 Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.   Do not clean the appliance with any chemicals.  Ensure the unit is far away from fire, inflammable, or explosive objects.  The unit shall be installed in accordance with national wiring regulations. ...
  • Page 8 2.2 SAFETY PRECAUTIONS ON SERVICING Please follow these warnings when to undertake the following when servicing a dehumidifier with R290. 2.2.1 Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 9 Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: –...
  • Page 10: Instannation

    3. INSTALLATION 3.1 LOCATION Place the unit on a firm, level surface in an area with at least 20cm of free space around it allow for proper air circulation. Never install the unit where it could be subject to: Heat sources such as radiators, heat registers, stoves or other products that products ...
  • Page 11 3.2 OPERATING THE DEVICE SAFELY Check the device after unpacking for any damages or scratches on it.  Operate this unit in an ambient temperature from 5°C to 35°C.  Do not use outdoors. This dehumidifier is intended for indoor residential applications only. ...
  • Page 12: Product Overview

    4. PRODUCT OVERVIEW FRONT VIEW BACK VIEW...
  • Page 13   Low power consumption-energy efficient.  A 24 hours timer to set the time of operation.  Quiet fan has two speed settings. 4.3 SPECIFICATIONS MODEL NO. OL12-B015E 12L/day (30℃, RH80%) Dehumidify Capacity Rated Voltage AC220-240V Rated Frequency 50Hz Max.
  • Page 14: Operation

    5. OPERATION CONTROL PANEL ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ FUNCTION KEYS AND INDICATORS POWER button Press once to switch the machine on or off. Hum/CNT button Selects humidity set-point or continuous operating. Fan speed button Press to select fan speed between high and low.
  • Page 15 5.2 SETTINGS Operation mode setting Normal Operation Press POWER key to turn on the unit. Press the HUM/CNT key to activate the AUTO mode. The unit operates in auto mode with the default 60% humidity set-point. Continuous Operation Press POWER key to turn on the unit and operates in continuous mode automatically. The unit starts to dehumidify in continuous operation with the default 20% relative humidity.
  • Page 16 Water FULL Indicator The machine automatically shuts off once the water tank is full, alerting the user through an indicator light and buzzing for 15 times. It reminds you to check:  If the water tank is full, empty and re-install the water tank. ...
  • Page 17 5.3 DRAINAGE There are two ways of removal collected water produced by the unit. A. Manual draining: Empty water tank by manual. B. Continuous draining: Use gravity to drain condensate water by attaching a drain hose. 5.3.1 EMPTYING THE WATER TANK The water tank built in unit will fill up and shut the unit down once it is full.
  • Page 18 5.3.2 CONTINUOUS DRAINING For continuous operation or unattended dehumidification, please connect the attached drain hose to the Condensate water can be automatically flow into a bucket or drain by gravity. unit. Set the unit in a horizontal surface and stable position. ...
  • Page 19: Maintance

    6. MAINTENANCE CLEANING THE AIR FILTER (every two weeks) Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit. The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.
  • Page 20 CLEANING UP OF REFRIGERANT 1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level. 2. Eliminate every possible source of ignition. 3. Use appropriate personal protection equipment (PPE). 4. Evacuate unnecessary personnel, isolate, and ventilate area. 5.
  • Page 21: Troubleshooting

    7. TROUBLESHOOTING SYMPTOM INSPECTION SOLUTION  Insert the power cord securely into the  Check the power connection in securely. wall Outlet.  Check if the water level indicator lights  Empty the water tank and reinstall The unit is not correctly.
  • Page 22 8. DECOMMISSIONING 8.1 STORAGE Long-term storage - If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps: Unplug the unit.
  • Page 23 This product imported by: Consumable Direct Ltd M32 0JT...