Installation sequence
Sequence overview
Sequence
Installation
1
Check system requirements.
2
Fit wall mounting bracket for Vitoconnect 100.
3
Connect the Vitoconnect 100 to the heat generator.
4
Insert the Vitoconnect 100 into the wall mounting
bracket.
5
Establish power supply.
Commissioning
6
Check network settings.
7
Register user and set up heating system.
Operation with ViCare app
Operation with Vitotrol Plus App

Installation location

Fig. 2
Sample illustration with wall mounted appli-
ance
To ensure a good WLAN connection, keep the dis-
A
tance between the Vitoconnect 100 and the WLAN
router as short as possible.
10
Installation type: Wall mounting
Note
A
When selecting the installation site, bear in mind the
length of the connecting cables (standard delivery).
Connecting cables/leads
Connecting lead Optolink/USB for con-
necting the Vitoconnect 100 to the boiler
control unit
>0.3 m
Plug-in power supply unit with connect-
ing cable
Responsibility
Heating contractor/IT expert
Heating contractor
Heating contractor
Heating contractor
Heating contractor
IT expert
Heating contractor/system user
Distance to heat generator minimum 0.3 m
Standard socket 230 V/50 Hz, max. 1 m next to
installation location
Internet access with adequate WLAN signal
Note
The WLAN signal strength can be increased with
commercially available WLAN repeaters.