Specifications And Technical Data; Hydraulic Circuit - Comet FDX HOT CUBE Instruction Manual

Hot water high-pressure cleaner with combustion engine
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
EN
WARNING
MOTORISATION
Fuel
Power
Engine
Starting
Nominal rotation speed - maximum

HYDRAULIC CIRCUIT

Maximum supply water temperature
Minimum supply water temperature
Minimum supply water flow rate
Maximum supply water pressure
Maximum priming depth
PERFORMANCE
Maximum flow rate
Nominal flow rate
Max pressure with water outlet temperature
up to 110 °C - 230 °F
Max pressure with water outlet temperature
up to 140 °C - 284 °F
Nominal pressure with water outlet temperature
up to 110 °C - 230 °F
Maximum reaction force on the spray gun
Sound pressure level - Uncertainty
Sound power level
Operator hand-arm vibration - Uncertainty
PUMP OIL
GEARBOX OIL
WEIGHT AND DIMENSIONS
Length x width x height
Weight
Engine fuel tank
Diesel tank
Anti scale tank
(1)
Measurements in agreement with EN 60335-2-79.
(2)
Also see the corresponding oils table.
CAUTION
• For the engine to reach its maximum power it needs at least 10 hours running-in at a load 15 to 20% lower than the machine' s maximum performance.
• The engine' s maximum power diminishes as the altitude and ambient temperature at which it is working increases (there is a drop of about: 3.5% every
305 m/1000 ft above sea level and 1% every 5.6°C/42°F above 16°C/61°F). If the high pressure water cleaner is used at a high altitude or with high ambient
temperature please refer to the engine' s operating and maintenance manual to see if any precautions need to be taken.
• The declared performance refers to an atmospheric pressure of 1013 hPa at sea level and an ambient temperature of 16°C/61°F.
• The specifications and technical data are approximate. The manufacturer reserves the right to make all changes to the machine it deems appropriate.
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
Read and keep in mind that indicated in the
MANUAL - SAFETY WARNINGS.

SPECIFICATIONS AND TECHNICAL DATA

(kW - HP)
(RPM)
(°C - °F)
(°C - °F)
(l/min - USgpm)
(bar - psi)
(m - ft)
(l/min - USgpm)
(l/min - USgpm)
(bar - psi)
(bar - psi)
(bar - psi)
(N)
(dB(A))
(dB(A))
(m/s
(mm - in)
(kg - lb)
(l - USgal)
(l - USgal)
(l - USgal)
16/200B
21/160B
PETROL
9,6 - 13
Honda GX390
3400 – 3600 [1560 - 1650
20 - 5,3
27 - 7,1
0,0
(TRAILER)
16 - 4,2
21 - 5,5
14,4 - 3,8
18,9 - 5,0
200 - 2900
160 - 2320
190 - 2755
150 - 2175
42
50
2
)
AGIP ROTRA MULTI THT
1200x800x950 - 47,2x31,5x37,4
220 - 485
6,1 - 1,61
2 - 0,53
(*) Gearbox R = 1 : 2,18.
INSTRUCTION
FDX HOT CUBE
16/200D
DIESEL FUEL
5,5 - 11
Yanmar L100V
ELECTRICAL
]
(*)
60 - 140
5 - 41
20 - 5,3
8 - 116
/ 1,0 - 3,3
(SKID)
16 - 4,2
14,4 - 3,8
200 - 2900
32 - 464
190 - 2755
42
(1)
89 - 0,7
(1)
107
(1)
3,9 - 0,24
(2)
80W-90
240 - 529
4,7 - 1,24
30 - 7,9
/ NO
(TRAILER)
(SKID)
EN
21/160D
27 - 7,1
21 - 5,5
18,9 - 5,0
160 - 2320
150 - 2175
50
21