AAF Flanders AstroPure 500-IR Installation, Operation And Maintenance Manual

AAF Flanders AstroPure 500-IR Installation, Operation And Maintenance Manual

Portable air purification system

Advertisement

Quick Links

AstroPure
Portable Air Purification System
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for AAF Flanders AstroPure 500-IR

  • Page 1 AstroPure ™ Portable Air Purification System INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...
  • Page 2: Table Of Contents

    Filter’s Pressure Drop and Particulate Matter Counting Screen ........... 15 Decontamination and Other Set-up Screen .................. 15 Operational Timer / Programming Screen ..................16 Trouble Shooting Guide ........................17 Warranty ............................... 18 Manual Revision History ........................19 Contacting AAF Flanders ........................20...
  • Page 3: Introduction And Precautions

    These instructions are specific to the AAF Flanders AstroPure Air Purification System. All ancillary tasks including, but not limited to, electrical and mechanical work, equipment handling, and safety procedures must be performed in accordance with industry-accepted practice and all relevant local, state, and federal government codes, laws, and policies.
  • Page 4: Important Safety Instructions

    Contaminants removed may include dust, pollen, mold, bacteria, and viruses. AstroPure Principle of Operation The AAF Flanders AstroPure Air Purification System is not intended for use as a dust/smoke extraction system for remediation of a “dirty” environment. Use as such will result in significantly...
  • Page 5: Product Overview & Installation Instructions

    PRODUCT OVERVIEW & INSTALLATION INSTRUCTIONS Platform Overview The AAF Flanders AstroPure Air Purification platform includes two capacity ranges: a 0-500CFM and 500-1000CFM unit. Part Number Model Number Additional Description 393-500-100 AstroPure 500 IR Indoor Portable Unit – Air Recirculation – 0-500CFM...
  • Page 6: Specifications

    PRODUCT OVERVIEW & INSTALLATION INSTRUCTIONS (CONT’D) Specifications Product Model AstroPure 500-IR AstroPure 500-IE AstroPure 1000-IR AstroPure 1000-IE Internal portable unit - Internal portable unit - Internal portable unit - Internal portable unit - recirculation mode exhaust air mode recirculation mode exhaust air mode Non-ducted Ducted (12"...
  • Page 7: Unpacking

    PRODUCT OVERVIEW & INSTALLATION INSTRUCTIONS (CONT’D) Unpacking Carefully remove the equipment from the shipping carton and inspect for any damage that may have occurred during transportation. Two workers at minimum are required to lift the unit from the container. Remove unit from shipping carton. Ensure when the unit is removed from the package that it is placed upon smooth, level, and stable ground.
  • Page 8: Installation Instructions

    5. Unlock the caster wheels. a. AAF Flanders AstroPure Air Purification Systems come with pre-installed caster wheels and filters. There is no required assembly of these items. 6. Carefully move the unit to the desired location of service.
  • Page 9: Quick Start Guide & Operation

    QUICK START GUIDE & OPERATION Quick Start Guide 1. Read and observe all safety and installation instructions provided in the Introduction and Installation Instructions section of this document. 2. After completion of installation, turn on the power switch located on the back of the unit. 3.
  • Page 10: Air Flow Calculation

    QUICK START GUIDE & OPERATION (CONT’D) Air Flow Calculation Per ASHRAE guidelines and other relevant guidelines, the feet coverage of each unit can be calculated using the following example: CFM = (Ceiling Height) x (Room Square Footage) x (ACH) x (1hr/60min) As an example, if the unit is installed in a 35’...
  • Page 11: Ec Motor Speed Adjustment

    QUICK START GUIDE & OPERATION (CONT’D) EC Motor Speed Adjustment The unit has been equipped with an EC motor and controller to allow customization of air flow settings or noise levels. This adjustment can be done directly in the control panel (see Control Panel section for more information).
  • Page 12: Wiring Diagram

    QUICK START GUIDE & OPERATION (CONT’D) Wiring Diagram Motor Specification AstroPure 1000 EC motor - 1 HP – 11.45 Amp – 115/120 V – 50/60 Hz - 1phase - 15 Amp fuse - Rotation: counter-clockwise - Motor must start at 1 +/- 0.2 VDC, 10% PWM, AT 600 +/- 10 RPM AstroPure 500 EC motor - 0.33 HP –...
  • Page 13: Maintenance & Service

    MAINTENANCE & SERVICE Filter Replacement Important note: The filters can be contaminated with various particles, including viable and potentially infectious contaminants. If it is suspected that filters could be contaminated with infectious contaminants, it is recommended that before starting filter replacement, all designated PPE devices must be available, in good condition, and used during filter replacement.
  • Page 14: Replacement Parts

    The HEPA filter can last up to 24 months, depending on indoor air contamination levels. It is recommended to replace it over an interval of 12-24 months. For additional information, see the section of this manual on contacting AAF Flanders. Efficiency...
  • Page 15: Control Panel

    CONTROL PANEL The AAF Flanders AstroPure contains an intuitive six-button control panel (HMI). ™ Available functions and features are described below. • Graphic display with visual alarms and alerts • On/off schedule programming that promotes energy savings • Programmable decontamination cycle for cleaning the air faster •...
  • Page 16: Filter's Pressure Drop And Particulate Matter Counting Screen

    CONTROL PANEL (CONT’D) Filter’s Pressure Drop and Particulate Matter Counting Screen Decontamination and Other Set-up Screen Operational Timer / Programming Screen...
  • Page 17: Operational Timer / Programming Screen

    CONTROL PANEL (CONT’D) Control Panel - Functions and Programming Table Screen Button Action Fan's power UP DOWN Fan's power DOWN Enter Next screen Return Previous screen On/Off Turn the fan On or Off Main Screen Function + Return Change the lock position (open or closed) Function + Enter Turn off the programming hours Hold Enter...
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Check for blown fuse. Check for loose power cord. No Equipment Power Ensure power switch is in on position. Inspect wall receptacle. Ensure kill switch on back panel is in closed position. Check whether prefilter or HEPA filter require replacement. Low Air Velocity Increase speed setting on the control panel.
  • Page 19: Warranty

    To obtain assistance under this limited warranty please contact the selling agency. To obtain information or to gain factory assistance, contact AAF International Warranty Claims Department, 9920 Corporate Campus Drive, Suite 2200, P.O. Box 35690, Louisville, Kentucky 40223-5000; Telephone (502) 637- 0011, FAX (888) 223-6500.
  • Page 20: Manual Revision History

    APPENDIX B – MANUAL REVISION HISTORY Revision Revision Date Description of Change Approval Version 12/24/2020 Initial edition Revision B – adding new information about control 03/25/2021 panel...
  • Page 21: Contacting Aaf Flanders

    Momence, IL Yuki, Japan (Nippon Muki) Smithfield, NC Contact your local AAF Flanders representative Tijuana, Mexico for a compete list of AAF Flanders Air Filtration Votorantim, Brazil Product Solutions. Washington, NC AAF Flanders has a policy of continuous product research and improvement. We reserve the right to change design and specifications without notice.