Electrical Operation

IMPORTANT: The electrical installation should be carried by qualified
person only.
Please note the wire color code while connecting the 2x mains cable:
G: green/yellow color = Ground earth connection
N: blue color = Neutral
L: brown color = Live
This device must be earthed to comply with regulations!
This device can NOT be dimmed, do not connect on a dimmer pack!

Maintenance and Cleaning

The following points have to be considered during the inspection:
* All screws and parts of the device have to be tight and may not be
corroded.
* There may not be any deformations on the housing, color lenses,
fixations and installation spots (ceiling, suspension, trussing).
* The electric power supply cables must not show any damage, material
fatigue or sediments.
In order to maintain the device in good condition and extend the life time,
we recommend to clean the device frequently.
The cleaning of heat sink and external optical lenses must be carried out
periodically to optimize light output. The frequency of cleaning depends
on the environment in which the fixture operates.
A detailed electric check by certified electrician each three month,
7