Download Print this page

Advertisement

Quick Links

Installation Instructions
Rionfuse CF
Rionfuser™ 3000LE Bluetooth
Rionfuser™ 3000LE LT
Rionfuser™ 3000LE USB
Polypropylene and PVDF Chemical Waste
Systems
WARNING
!
DANGER
!
Electricity, electrocution
and shock hazards.
WARNING
!
Local building or plumbing codes
may require modifications to
the information provided. You
are required to consult the local
building and plumbing codes prior
to installation. If the information
provided here is not consistent
with local building or plumbing
codes, the local codes should be
followed. This product must be
installed by a licensed contractor
in accordance with local codes
and ordinances.
NOTICE
Follow the guidelines listed here for
proper installation, operation, and
maintenance.
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can result in death,
serious personal injury, property damage, or damage to the equipment.
Keep this Manual for future reference.
®
RF 3000LE

Advertisement

loading

Summary of Contents for Watts ORION RF-3000LE

  • Page 1 Installation Instructions Rionfuse CF Rionfuser™ 3000LE Bluetooth ® Rionfuser™ 3000LE LT Rionfuser™ 3000LE USB Polypropylene and PVDF Chemical Waste Systems WARNING Read this Manual BEFORE using this equipment. Failure to read and follow all safety and use information can result in death, serious personal injury, property damage, or damage to the equipment.
  • Page 2: Calibration Recommendations

    Service Contact Information Calibrating your Rionfuser™ Electrofusion Processor: 1. Send the processor to a WATTS service center and let our technicians do it. Call (302) 451-1088 to make arrangements for service and to obtain an RMA number for the return.
  • Page 3 RF-3000LE Product Overview Rionfuser™ Electrofusion Processor Connection Sizes: 1.5" – 12" (38mm to 305mm) The Rionfuser™ RF-3000LE electrofusion processor is a reliable, easy-to-use, rugged tool designed to withstand conditions found at typical construction sites. It comes with an integral splash-proof and shock resistant outer suitcase-style enclosure.
  • Page 4: Installation Instructions

    Due date has passed or is within the life of your project, then STOP, and con- tact your Orion Representative for instructions on how to get your machine recalibrated. Watts disclaims all liability for installations performed with a Rionfuser past its calibration date.
  • Page 5 Step 3 Joint Assembly Insert the prepared ends of the pipe/fitting into both hubs of the Rionfuse CF coupling. Double check the markings to verify proper seating of the pipe. Insert into coupling and verify proper seating Step 4 Connecting Lead Cables The installer must make sure the joint is properly supported during the fusion cycle and afterwards as the joint cools to ambient.
  • Page 6 Step 6 Selecting Pipe Size Next the unit will prompt the installer to select the size of the joint being fused. Scroll UP or DOWN to highlight the correct size, then press START to select size. Fitting size selection screen Step 7 Selecting Heat Cycle The unit will ask if a pre-heat cycle is needed for the joint.
  • Page 7 Step 9 Successful Weld Completion After pressing START, the Rionfuser™ will begin the weld. After the welding cycle has completed, another audible beep will sound to indicate that the fusion weld is complete. If the beeping pattern is an equal, consistent beeping, the joint was successful.
  • Page 8 USB to Serial Port adapter. This adapter is available for purchase from WATTS. One adapter may be used with multiple processors. The pictures below show a 9 pin D-sub connector and the installed adapter for your reference.
  • Page 9 Downloading Wirelessly Fusion data from an RF-3000LE Bluetooth Electrofusion Processor is downloaded wirelessly ® through the EF Utilities app. Once data has been downloaded, it can be viewed at any time with a smart phone, tablet, or computer. To download fusion data from the processor to the EF Utilities app, perform the following steps: 1.
  • Page 10: General Maintenance

    The processor will countdown the number of days until calibration is due. The text mm/dd/yyyy shows the month, day, and year that the calibration is due. To avoid being locked out of the processor, WATTS recommends scheduling a calibration as soon as it starts to display this reminder message.
  • Page 11 ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. USA: T: (800) 334-6259 • OrionFittings.com Canada: T: (888) 208-8927 • F: (905) 481-2316 • OrionFitting.ca Latin America: Tel: (52) 55-4122-0138 • OrionFittings.com IS-OR-Rionfuse CF 2141 EDP# 1915462 © 2021 Watts...