Summary of Contents for IMPLOX Newborn Anne

  • Page 2: Table Of Contents

    UIDE Newborn Anne Package Contents ....3 Manikin Connectors ......4...
  • Page 3: Introduction

    ETUP UIDE IMULATION Introduction and Intended Use Newborn Anne Manikin Newborn Anne focuses on training in basic neonatal resuscitation skills. Newborn Anne M M anikin Features Airway Features: • Anatomically accurate, realistic airway • ET tube insertion • LMA insertion •...
  • Page 4: Setup Guide

    LINICAL ETUP UIDE NTRODUCTION IMULATION MAINTENANCE Setup Guide Newborn Anne Package Contents The following parts are included in the Newborn Anne shipping carton. Newborn Anne Manikin IV Bag Connector Tube Umbilical Liquid Simulated Cord (1) Soap Blood Pulse Bulb Tube...
  • Page 5: Manikin Connectors

    UIDE MAINTENANCE Manikin Connectors The Newborn Anne manikin is shipped ready for use. * To attach an empty IV Bag (not provided), connect the IV Bag Connector Tube (C) to the manikin’s Umbilical Reservoir Tube Connection (D). * To attach the Umbilical Pulse Bulb Tube (B), connect to the manikin’s Umbilical Pulse Bulb Tube Connection (A).
  • Page 6: Clinical Simulation

    MAINTENANCE Clinical Simulation Using the Newborn Anne Manikin 1. General Handling Newborn Anne is the size and weight of a newborn baby girl delivered at term with approximately 3.5 kg (7 lbs) body weight and 51 cm (21 inches) length.
  • Page 7 UIDE IMULATION MAINTENANCE Clothing: The Newborn Anne manikin is delivered with baby pants with snaps at the bottom to allow tubing to pass through. Powdering: Newborn Anne manikin is delivered with powder. When needed, apply light dusting of powder externally to the manikin...
  • Page 8: Airway Simulation Features

    UIDE MAINTENANCE 2. Airway Simulation Features Opening the Airway The neck of Newborn Anne manikin is realistically flexible, from hyperextension to flexion. The simulation team members may demonstrate correct head position for opening of the airway. Clearing the Upper Airway...
  • Page 9 Cricoid pressure may be used by the simulation team member. The Newborn Anne manikin jaw is realistically hinged and flexible, for airway and intubation maneuvers. The Newborn Anne manikin vocal cords are realistically shaped and at a depth of 9.5 cm from the upper lip.
  • Page 10 (fourth intercostal space) into the pleural space. The rib structure can be palpated through the skin. The Newborn Anne manikin's pleural space is enclosed so that the needle cannot damage the inner components of the manikin.
  • Page 11: Drug & Iv Administration

    LINICAL NTRODUCTION ETUP UIDE IMULATION MAINTENANCE 3. Drug & IV Administration IV Access via the Umbilical Vein IV fluids or simulated medications may be injected into the vein in the umbilical cord. The fluids will accumulate in an abdominal fluid reservoir (40 ml capacity) if the reservoir is not filled to use the manual pulse.
  • Page 12: Manikin Preparation Before Use

    LINICAL IMULATION MAINTENANCE NTRODUCTION ETUP UIDE Manikin Preparation Before Use Inserting Fluids into the Umbilical Reservoir Use a syringe to insert fluid into the abdominal reservoir. Do not fill more than 40 ml. Attaching the Umbilical Cord Lubricate the end of the umbilical cord to be inserted with liq- uid soap.
  • Page 13 Units 22-24 60-66 Richmond Road, Keswick 5035, South Australia Telephone: 8351 1455 Facsimile:8293 7377 Email: CustomerService@implox.com www.implox.com...