PUMP OPERATION

IMPORTANT: Make sure the pump is upright when using the spa.
Heating Reset
When using the Lay-Z-Spa for first time, or after a long period of inactivity, be sure to
press the reset button on the pump using a small and thin object.
IMPORTANT INSTRUCTIONS FOR USING
If the temperature on the control panel (or the water temperature) has not changed 4-5 hours after
activation of the heating system, use a thin object to press the RESET BUTTON, and restart the
heating system.
IMPORTANT: The heating System will not operate if the outside temperature is above 40ºC (104 ºF)
or if the Lay-Z-Spa is under direct sunlight. Under these conditions, please wait until a cooler time of
day before pressing the RESET BUTTON with a thin object and restart the heating System.
Lock/Unlock Button
The pump has a 5-minute auto-lock. The LED light will dim out when the pump is locked (no function is activated). To lock or unlock the pump,
place a finger over the lock/unlock button for 3 seconds.
Power-Saving Timer Button
This is a newly added function, designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa.
This way, you can enjoy your spa at the time you desire, without needing to leave the heater on at all times.
STEP 1: Set the heating duration
1. Press the
button unit the
2. Press the
or
button to adjust the heating duration (From 1-999 hours).
3. Press the
button again to confirm the heating duration.
STEP 2: Set the number of hours FROM NOW when the heater will activate
1. After setting the heating duration, the
2. Press the
or
button to adjust the hours until time of activation (From 0-999 hours).
3. Press
button again or simply touch nothing for 10 seconds to confirmthe setting. The
begin.
To modify the timer settings: Press the
Cancel the setting: Press the
NOTE: After setting, the screen flashes the current temperature and time alternately.
NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 999 hours; Reservation time adjustment (the number of hours FROM NOW
when the heater will begin to function) may be set from 0 to 999 hours. If the timer is set at 0 hour, the heating system will activate immediately.
Note that the timer is one time per use - the user sets the duration of the heating cycle, and how many hours from now the heating cycle begins. The timer
does NOT repeat until reset.
Lay-Z-Massage System Button
Use this button to activate the massage system, which has a 30-minute auto-shutoff feature. The light above the Lay-Z-Massage System
Button displays red when activated.
IMPORTANT: Do not run the Lay-Z-Massage system when the cover is attached. Air can accumulate inside the spa and cause
irreparable damage and bodily harm.
NOTE: Heat and massage system work together to create a warm massage experience.
Celsius/Farenheit /Wi-Fi Toggle
This button has two functions:
The temperature can be displayed in either Fahrenheit or Celsius.
This button has a Wi-Fi activation function. For more information, please refer to Wi-Fi operation instructions. In the up part of the control panel,
there is the Wi-Fi LED status.
This LED indicates the status of the Wi-Fi connection. Check in the alarm section for the different statuses of this LED.
Heat Button
Use this button to activate the heating system. When the light above the heat button is red, the heating system is activated. When the
light is green, the water is at the set temperature and the heating system is at rest.
NOTE: If the heating system is activated the filtration system will automatically start.
NOTE: After turning off the heating system the filtration system will continue to operate.
NOTE: If the PRCD is activated and the water temperature is below 6ºC, it will automatically heat to 10ºC.
Water Filter Button
This button turns the filter pump on and off. The light above the Water Filter Button displays red when activated.
NOTE: The heating and filtration systems do not turn off automatically. When finished using either system, be sure to turn them off.
Temperature Adjustment Buttons
Pressing the Temperature Increase or Decrease buttons will cause the LED to flash. When it is flashing you can adjust to the desired temperature
setting. If you hold these buttons down the values will rapidly increase or decrease. The new and desired temperature setting will remain on the LED
display for 3 seconds to confirm the new value.
NOTE: The default temperature is 35°C (95°F).
NOTE: Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
On/Off Button
Press this button for 2 seconds to active the control panel bottons and the light turns to green. Press this button for 2 seconds to turn off all currently
activated functions.
Power-Saving Timer LED
This LED flashing means you are setting the heating duration. The light will be on when the heating function starts to work.
This LED flashing means you are setting the number of hours FROM NOW when
the heater will activate. When the light is on, the Power-Saving Timer function is set.
NOTE: The water heat rate may change in the conditions below:
• When the outdoor temperature is below 15°C (59°F).
• If the cover is not in position when the heating function is activated.
NOTE: To display the current water temperature, run the filter system for at least a minute. The water temperature as tested by an external
thermometer may vary from the temperature as displayed on the spa panel by as much as approximately 2°C.
WARNING: If the outdoor temperature is below 4°C and the pump does not work due to a power outage, this could result the pool or pump to freeze.
Any damage as a result of using the spa in these conditions is the responsibility of the customer. Do not use the spa when the ambient temperature
reaches -10°C.
303021213663_14.0x21.0cm_54184AU_澳规AirJet SPA说明书
RESET BUTTON
LED starts to flash.
LED starts to flash.
button and use the
or
button to adjust.
button for 2 seconds.
RESET
LED will light steadily, and the countdown to heater activation will
10