Summary of Contents for Baldwin Boxall VIGIL EVAS BVRD2M

  • Page 1 C O M M U N I C A T I O N S VIGIL EVAS BVRD2M Operating Instructions Manual name: BVRD2M Issue: 2 ECN: 3082 Date of issue: August 2016 www.acornfiresecurity.com...
  • Page 2 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S This equipment has been designed and manufactured to conform to the following EC Standards: EMC: EN55103-1 Environment Classification: E1, EMC: EN55103-2 Environment Classification: E5,...
  • Page 3: Table Of Contents

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Amendment Record ___________________________________ v Proprietary Notice ____________________________________ v Safety Information ___________________________________ vi Comments_________________________________________ vi Introduction BVRD2M Technical Description __________________________1 Front Panel Controls & Settings __________________________2...
  • Page 4 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Navigating the Menu Structure and Setting Parameters ________ 22 System Configuration - Audio Settings Audio Input Settings: General Description__________________ 23...
  • Page 5: Amendment Record

    Baldwin Boxall Communications Limited. The possession of this manual and the use of the information is, therefore, restricted only to those persons duly authorised by Baldwin Boxall Communications Limited. Do not reproduce, transcribe, store in a retrieval system or translate into any language, any part of this manual without the prior permission of Baldwin Boxall Communications Limited.
  • Page 6: Safety Information

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S AFETY NFORMATION Personnel who install, maintain or repair this equipment must read the safety information below before starting work. Voltages in excess of 30 Volts RMS or 50 Volts DC are considered Hazardous and in certain circumstances can be lethal.
  • Page 7: Bvrd2M Technical Description

    1 Introduction 1.1 BVRD2M T ECHNICAL ESCRIPTION The VIGIL EVAS BVRD2M is a DSP controlled Voice Alarm Routing Matrix that is fully compliant with BS5839 part 8 and EN54 part 16. The BVRD2M master unit provides eight electronically balanced inputs, each with 3 band parametric (plus bass and treble) equalisation, an optional limiter / compressor, and independent priority settings.
  • Page 8: Front Panel Controls & Settings

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.2 F & S RONT ANEL ONTROLS ETTINGS Figure 1.1 — BVRD2M Front Panel Access Control / System Unless Key is turned (and password entered), access to...
  • Page 9: Rear Panel Connections

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.3 R ANEL ONNECTIONS Figure 1.2 — BVRD2M Rear Panel Dual 24V PSU Inputs The BVRD2M requires two seperate 24V DC supplies.
  • Page 10: Bvrd2M Specifications

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.4 BVRD2M S PECIFICATIONS 1.4.1 Audio Input Specifications Input Sensitivity 80mV (-20dB) to 3V (+12dB) Frequency Response -3dB @ 30Hz and 20KHz...
  • Page 11: Audio Output Specifications

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.4.2 Audio Output Specifications Nominal Output Level 0.775dB (0dB) Maximum Output Level 4.5V (+15.5dB) Frequency Response -3dB @ 30Hz and 20KHz...
  • Page 12: Bvrd2S Slave Unit

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.5 BVRD2S S LAVE 1.5.1 Main Features Adding a BVRD2S to a BVRD2M increases the number of inputs available by 12, the number of outputs by 16 and adds another 12 messages.
  • Page 13: Bvrd2M Canbus Modules

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.7 BVRD2M CANBUS M ODULES There are currently five CANBUS modules available: 1.7.1 BVRDACO / BVRDNCO • 10 x BEL line surveillance with earth leakage fault detection...
  • Page 14: Simplified Schematic Diagrams

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.8 S IMPLIFIED CHEMATIC IAGRAMS 1.8.1 BVRD2M & BVRD2S Schematic Diagrams Figure 1.4 — BVRD2M Schematic Diagram BVRD2M issue 2...
  • Page 15 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Figure 1.5 — BVRD2S Schematic Diagram BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 16: Can Bus Module Schematic Diagrams

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.8.2 CAN BUS Module Schematic Diagrams Figure 1.6 — BVRDACO Loudspeaker Line Monitor BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 17 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Figure 1.7 — BVRDACO Amplifier / Line Fault Detection BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 18 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Figure 1.8 — BVRDFPI Fire Panel Interface BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 19 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Figure 1.9 — BVRDCI Access Interface Module BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 20: Typical Installation Examples

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 1.9 T YPICAL NSTALLATION XAMPLES Figure 1.10 — Typical 15 Zone Single Circuit Wiring Diagram BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 21 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S Figure 1.11 — Typical 15 Zone Dual Circuit Wiring Diagram BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 22 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S BVRD2M issue 2 www.acornfiresecurity.com...
  • Page 23: Hardware Installation

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 2 Hardware Installation The BVRD2M and BVRD2S are both housed in 1 unit 19" Rack Mount chassis. AUTI ON It is important that slide rails or rack runners are used to support the weight of the unit(s) when installed.
  • Page 24 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S To attach a Slave unit: • First, remove the dust covers from the data link connectors on the Master and Slave units.
  • Page 25: Operating Instructions

    3 Operating Instructions 3.1 I NTRODUCTION The VIGIL EVAS BVRD2M is primarily configured using the USB Configuration Software, however all settings are also available on the 40 x 2 character LCD front panel display. The navigation controls as shown in Figure 3.1.
  • Page 26: Front Panel Navigation Controls

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 3.2 F RONT ANEL AVIGATION ONTROLS Figure 3.1 — BVRD2M Front Panel Access Control / Unless Key is turned (and password entered), access to...
  • Page 27: Access Levels

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 3.3 A CCESS EVELS There are five Access Levels to allow different personnel the relevant level of access to the system configuration options.
  • Page 28 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 3.4 N AVIGATING THE TRUCTURE ETTING ARAMETERS The "Multi Function Encoder", "Left", "Right", "Select" and "Back" buttons (as shown in Figure 3.1) are used to navigate through the menu structure.
  • Page 29: System Configuration - Audio Settings

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4 System Configuration - Audio Settings 4.1 A UDIO NPUT ETTINGS ENERAL ESCRIPTION The BVRD2M can accommodate up to 8 audio inputs, and using BVRD2S slave units the maximum number of inputs is increased to 68.
  • Page 30: Audio Output Settings: General Description

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4.2 A UDIO UTPUT ETTINGS ENERAL ESCRIPTION The BVRD2M provides up to 7 audio inputs, and using BVRD2S slave units the maximum number of outputs is increased to 87.
  • Page 31: Dva Message Settings: General Description

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4.3 DVA M ESSAGE ETTINGS ENERAL ESCRIPTION The BVRD2M DSP Module can store up to 6 messages, each up to 57.3 seconds in length. The messages and all have independent surveillance and timing adjustments.
  • Page 32: Bypass Inputs: General Description

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4.5 B YPASS NPUTS ENERAL ESCRIPTION There are three input sources that can bypass all signal processing devices, in the event of failure, to perform a broadcast to all zone outputs.
  • Page 33: Entering Or Changing Names Of Inputs / Outputs Etc

    VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4.6 E NTERING OR HANGING AMES OF NPUTS UTPUTS ETC The names of all Inputs, Outputs, DVA Messages, and Faults can be changed to suit the installation.
  • Page 34 VIGIL EVAS BVRD2M Operating Instructions C O M M U N I C A T I O N S 4. Turn the Rotary Encoder to select the required character. Audio O/P 03 (Rud OP 03 [Zone*][Listen ][Reserve ] 5. Press the “Right” key to step to the next character.

Table of Contents