AUTO SWEETENER SET-UP (cont.)
5.
Plug brewer into the power source.
6.
Place an empty reservoir under the dilution nozzle of the brewer.
7.
Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise) 1/2
turn.
8.
Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (After approxi-
mately 3 minutes the sweetener will come out of the dilution nozzle.)
9.
Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.
10. Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or decreased
(Dilution cycle is usually between 3 to 3 1/2 minutes).
11. If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener dis-
pensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.
12. Set the "Delay" knob on the dilution timer back to the 6 to 7 minute setting.
13. After the desired volume has been set, turn the water supply on.
14. Reinstall the top lid, lower and upper rear panels.
The brewer may now be returned to service.
A. ON/OFF Switch
ON - Placing the switch in the left position allows the start switch to activate a timed brew cycle for three gallons
of tea.
OFF - Placing the switch in the right position stops the brew cycle. Stopping a brew cycle after it has been started
will not stop the flow of water into the funnel until the tank syphons down to its proper level. The switch should
always be placed in this position after a brew cycle and whenever the brewer is unattended.
B. Start Switch
Starts a brew cycle when the ON/OFF switch is in the "ON" position.
C. OFF/SELECTOR Switch (Models with Sweetener Only)
UNSWEET - Placing the switch in the left positional allows the start switch to activate a timed brew cycle for three
gallons of tea without sweetener.
OFF - Placing the switch in the middle position stops the brew cycle. Stopping a brew cycle after it has been started
will not stop the flow of water into the funnel until the tank syphons down to its proper level. The switch should
always be placed in this position after a brew cycle and whenever the brewer is unattended.
SWEET - Placing the switch in the right positional allows the start switch to activate a timed brew cycle for three
gallons of tea with sweetener.
CAUTION - CLEAN AND SANITIZE YOUR ICED TEA BREWER DAILY
1. Remove and thoroughly clean the entire brew funnel. The funnel tip and screen must be free from any tea
particles or residue. Reassemble the funnel.

OPERATING CONTROLS