Download Print this page

General Function - Sony FWD-50PX1 (English: pgs. 52-97 Protocol Manual

Monitors: 50" flat panel plasma display
Hide thumbs Also See for FWD-50PX1 (English: pgs. 52-97:

Advertisement

4. General Function

(a) Mode control
Syntax
Header
Control
0x8C
Enquiry
0x83
Answer
Header
Control
0x70
0x70
0x70
0x70
Answer
Header
Enquiry
0x70
Code Table (1-a)
[a]Function
0x00
Power
0x01
Input Select
0x02
Force Status Display
0x03
Audio Mute
0x04
Auto Status Display
0x05
Closed Caption
FWD-50PX1
Category
Function
0x00
Code Table (1-a) [a]
Answer
Check Sum
0x00
0x70
0x01
0x71
0x02
0x72
0x03
0x73
Answer
Return to Data Size
0x00
0x02
[b]Range/Switch Code
0x00
OFF
0x01
ON
0x08
INPUT1 RGB
0x09
INPUT1 COMPONENT
0x0A
INPUT2 RGB
0x0B
INPUT2 COMPONENT
0x0C
OPTION VIDEO
0x0D
OPTION S VIDEO
0x0E
OPTION RGB
0x0F
OPTION COMPONENT
0x00
ON1 (Signal)
0x01
ON2 (Clock)*
0x02
OFF
0x00
OFF
0x01
ON
0x00
ON
0x01
OFF
0x00
OFF
0x01
CC1
0x02
CC2
0x03
CC3
0x04
CC4
Data1
Data2
0x02
Code Table (1-a) [b]
0xFF
0xFF
Completed
Limit Over
Limit Under
Command Canceled
Return Data1
Check Sum
Code Table (1-a) [b]
0xXX
Command
Control
Enquiry
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Check Sum
0xXX
0xXX
Completed
Standby
Power On
Enable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Enable
Enable
Disable
Enable
5

Advertisement