Download Print this page

Communication Parameter; Pin Configuration; Communication Data Format - Sony FWD-42PX2 Protocol Manual

Flat panel display
Hide thumbs Also See for FWD-42PX2:

Advertisement

1. Communication Parameter

Communication system
Synchronous system
Baud rate
Character length
Parity
Start bit
Stop bit
Flow control

2. Pin Configuration

Display side (D-sub 9-pin)
FWD-42PX2
5
4
3
2
1
9
8
7
6
_ External view _
Pin No.
Signal
1
NC
2
TD
3
RD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
FWD-42PX2
RS-232C
Asynchronous communication
9600 bps
8 bit
None
1 bit
1 bit
None
Host side (D-sub 9-pin)
Personal computer
5
4
3
2
1
9
8
7
6
_ External view _
Pin No.
Signal
1
NC
2
RD
3
TD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC

3. Communication Data Format

(a) Control (Host
Request of Write to Display)
No.
Item
1
Header
2
Category
3
Function
4
Data1 (Length)
5
Data2 (Data1)
:
:
:
:
X
DataX
X+1
Check Sum
* Check Sum: The total from No. 1 to No. X, when value exceeds 255,1byte
of data is confirmed the bottom.
* Set the command interval to 500 ms or more when transmitting the
Control command continuously.
* Set the command interval to 500 ms or more when transmitting the same
command (Enquiry) after the Control command.
(b) Enquiry (Host
Request of Read to Display)
No.
Item
1
Header
2
Category
3
Function
4
Data1
5
Data2
6
Check Sum
* Check Sum: The total from No.1 to No.5, when value exceeds 255, 1byte
of data is confirmed the bottom.
Value
0x8C:Control
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
Value
0x83:Enquiry
0xXX
0xXX
0xFF
0xFF
0xXX
1

Hide quick links: