Insulation Resistance Test

1. Unplug the AC power cord and short the two prongs of the plug with a jumper wire.
2. Measure the resistance value with ohmmeter between the jumpered AC plug and all the terminals as shown in following
figures.
3. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
2.3.

Discarding of P.C. Board

When discarding P. C. Board, delete all personal information such as recorded images or scrap P. C. Board.
2.4.

Note For Repairing

1. Before carrying out repair, inform the user that there is a possibility of the user data inside the equipment becoming lost.
2. There is a possibility that the equipment to be repaired contains personal data or set data, so take adequate care.
3. When we loan you substitute equipment in order to carry out repair, please initialize the user data and setting data of the sub-
stitute equipment.