Original instructions Sunnan SUN30 ..2 ..12 ..22...
Page 2
SUN30 IMPORTANT: Keep this manual for future reference. Read the user manual carefully before operation. Further information is available in the user manual, service manual, and in the safety instructions for service. Service personnel are required to carefully read the user manual and service manual before operation.
Page 3
SUN30 Product Instructions Do not discharge the refrigerant into the The dehumidifier is used to remove excessive atmosphere. R-290 (propane) is flammable and moisture from the air. The resulting reduction heavier than air. in relative humidity protects buildings and their contents from the adverse effects of excess It collects first in low areas but can be humidity.
Page 4
SUN30 Safety Instructions Placement The appliance shall be disconnected from its When positioning the dehumidifier, ensure that power source during maintenance. it is placed on a level surface and that there is a minimum of 50 cm of space on either side Ensure the unit is far away from fire, of the unit to allow for efficient airflow.
SUN30 Parts and accessories Control panel 1. Plug the unit into a 230V earthed socket. 2. Press the ON/OFF button to turn on the unit. The dehumidifier will start to work in CONT mode (dehumidifies continously). If the dehumidifier isn´t turned off by the ON/OFF button or has been turned off for at least 3 min.
SUN30 Operating hour meter Continuous drainage When the dehumidifier is operated at high 1. The operating hour meter counts the temperatures and high humidity levels, the compressor operating time. water tank will require more frequent drainage. 2. The 5 first digits shows the operating time in In this situation, it may be more convenient to hours.
Page 7
SUN30 Trouble shooting The unit does not operate: Is the unit plugged in? Is the room temperature below 8°C or above 32°C? If so, then it is out of the working range of the unit. Ensure the ON/OFF switch is turned ON. Check that the water tank is positioned properly in the unit and that it is not full.
SUN30 Technical specification Type SUN30 Operating humidity range % RH 30-100 Operating temp. range °C +8 - +32 Power supply 220V - 240V~, 50 Hz Fuse Max. power consumption 500W / 2,2A Dehumidification test condition at liter / 24 h 20°C, 60% RH Dehumidification test condition at liter / 24 h...
Page 9
SUN30 Safety instructions for service No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing Please follow these warnings when to undertake the following when servicing a any pipe work that contains or has contained dehumidifier with R290.
Page 10
SUN30 Säkerhetsföreskrifter vid service Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks Checks to the refrigeration equipment and component inspection procedures. If a Where electrical components are being fault exists that could compromise safety, then changed, they shall be fit for the purpose no electrical supply shall be connected to the and to the correct specification.