Original instructions Sunnan SUN12 ..2 ..12 ..22...
Page 2
SUN12 IMPORTANT: Keep this manual for future reference. Read the user manual carefully before operation. Further information is available in the user manual, service manual, and in the safety instructions for service. Service personnel are required to carefully read the user manual and service manual before operation.
SUN12 Product Instructions • Do not discharge the refrigerant into the atmosphere. R-290 (propane) is flammable The dehumidifier is used to remove excessive and heavier than air. moisture from the air. The resulting reduction • It collects first in low areas but can be in relative humidity protects buildings and their circulated by the fans.
SUN12 Product Instructions • Do not use means to accelerate the defrosting process or to clean, other than ≥20cm those recommended by the manufacture. • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
SUN12 Parts List Figure 1 Components 1. Front Cover 2. Top Cover 3. Control Panel 4. Air Outlet 5. Handle 6. Air Inlet Filter 7. Water Tank 8. Rear Cover 9. Drainage Outlet 10. Power Cord Figure 2 Control Panel 11.
SUN12 Operating Instructions Start - stop dehumidifier Fan Speed Option (2S) (2S) Connect to the power supply and press the Press the fan speed button to select your (2S) power button once to turn on the unit, the unit preferred fan speed setting of low and high to runs by default mode on manual continuous meet the different usage requirements.
SUN12 Operating Instructions Cleaning When used regularly , the filter may become Low Temperature Defrost Indicator clogged with dust and particles. Therefore the filter should be cleaned at least every two weeks. Follow these steps: 1. Switch the device off and remove the plug from the socket before cleaning.
Page 8
SUN12 Display Error Codes Please contact local distributor if any of the error codes below appears. Display Code E1 Flash every 30 seconds E2 Flash every 30 seconds Error Temperature sensor error Humidity sensor error What is Device still dehumidifies but is in defrost Device still dehumidifies but is in continuo- happening mode only.
Page 9
SUN12 Checks to electrical devices Safety instructions for service Repair and maintenance to electrical components shall include initial safety checks Checks to the refrigeration equipment and component inspection procedures. If a Where electrical components are being fault exists that could compromise safety, then changed, they shall be fit for the purpose no electrical supply shall be connected to the and to the correct specification.
SUN12 Trouble shooting Problem Possible cause Solution Insert the plug into the wall The power is not connected outlet The device The water tank is full Empty the tank does not work The tank has not Replace the tank been replaced correctly Water removal capacity is too low Be patient and wait Water removal...
SUN12 Technical data Model SUN 12 Power supply 220-240V/50Hz Temperature range 8 till 35 °C Coolant R-290 Amount of coolant 45 g 4,2 liter/day at 20 °C,RH 60% Dehumidifying capacity 12 liter/day at 30 °C,RH 80%. Water tank volume 2,6 l Power 155 W Current...