Page 1
CPC514 3U CPCI Serial Elbrus CPU Module User Manual Rev. 002 November 2020 The product described in this manual is compliant with all related CE standards.
Transportation, Unpacking and Storage ………………………………………………………………………...………….9 Introduction ............................11 General features ............................11 Differences in the general features of the CPC514RC Module ………………………………………………..13 CPC514 Module versions ........................... 13 Delivery checklist of the module…………………………………………………………………………………...13 Packaging information………………………………………………………………………………………………14 Location of elements………………………………………………………………………………………………..14 Functional description ........................21 Block diagram .............................
Assignment of pins of the JTAG connector for XS6 processor debugging ........26 Table 2-6: Assignment of COM1 connector contacts and DisplayPort XP1 settings ........27 Table 2-7: Designations and functions of the LEDS in CPC514/CPC514RC ........... 27 Table 2-8: Assignment of configuration switches....................28 Purpose of the configuration switches …………………………………………………………………….37 Table 3-1: Power supply voltage …………………………………………….………………………………………...40...
This document contains information, which is property of Fastwel Co. Ltd. It is not allowed to reproduce it or transmit by any means, to translate the document or to convert it to any electronic form in full or in parts without antecedent written approval of Fastwel Co. Ltd. or one of its officially authorized agents.
Page 6
CPC514 Ownership rights This document contains information that is the property of Fastwel Group. It may not be copied or transmitted by any known means, nor may it be stored in information storage and retrieval systems without the prior written consent of Fastwel Group or one of its authorized agents. The information...
CPC514 Conventions Caution, High Voltage! This sign and text warn of the dangers associated with electrical discharges (> 60 V) when touching the device or any part of it. Failure to follow the precautions mentioned or prescribed in the regulations may endanger your life or health, and may result in damages to the equipment.
Page 8
CPC514 Safety requirements This Fastwel Group product has been developed and tested to ensure compliance with electrical safety requirements. Its design provides long-term fail-safe operation. The product's life cycle may be significantly shortened due to mishandling during unpacking and installation. Therefore, for your own safety and for ensuring proper operation of the device, you should follow the recommendations given below.
Fastwel Group other than those contained in this User Manual or received from the technical support service of Fastwel Group in the form of a set of instructions for their implementation will void the warranty.
Page 10
CPC514 For customized products, the warranty period is 60 months from the date of sale (unless otherwise provided by the delivery agreement). Limitation of warranty obligations The above warranty does not apply to: - the products (including software) that have been repaired or modified by the employees who do not represent the Manufacturer.
CPC514 Transportation, Unpacking and Storage Transportation The modules should be transported in the separate manufacturer’s packaging (container), consisting of an individual antistatic packaging and a cardboard box, in closed transport (road, rail, air in heated and sealed compartments) under storage conditions 5 according to the GOST standard 15150-69 or under storage conditions 3 for sea transportation.
Page 12
If a product should fail through Fastwel's fault during the warranty period, it will be repaired free of charge. For out of warranty repairs, the customer will be invoiced for repair charges at current standard labor and materials rates.
The CPC514 module is used in forced air cooling systems, while the CPC514RC module is intended for conduction cooled systems.
Page 14
CPC514 USB 2.0 ports: - 2 x ports are routed to the front panel connectors; - 7x ports are routed to the J3 CPCI Serial connector. Ethernet 10/100/1000 Mb/sec interface: - 2 x ports are routed to the front panel connectors;...
-50 to +70 ºC For the CPC514-01 version you will need to use forced cooling with the flow rate of no less than 0.5 m/s. Note 1. When ordering a product with the conformal coating option, suffix “/COATED”...
CPC514 1.5 Packaging information The CPC514 and CPC514RC modules are packaged in a box with the following dimensions: 230 x 150 x 45 mm. Table 1 - 3 – Packaging information CPC514 0,75 Packaged module weight, in kg, no more than...
Page 21
Figure 1-7 demonstrates the front panel of the CPC514 module. The extractor button (shown as “button A”) performs a mechanical function: it is used for installing / removing the CPC514 module (see subparagraph 3.2 Installation Procedure and 3.3 Module Removal Procedure). You can also use the extractor button to manually activate and deactivate module.
Page 22
CPC514 Figure 1-8 shows the front panel of the CPC514RC module. The extractor’s handles fulfill a mechanical function: they are used for installing/removing the CPC514RC module. Opening for a fixing screw of the front panel Top screw of the wedging mechanism...
CPC514 2.2 Specific features of the functional nodes operation Elbrus-4S Multi-core general-purpose high-performance microprocessor built compliance with the improved “Elbrus” architecture. The Elbrus-4S is a system on a chip (SoC) containing 4 computing cores, L2 cache memory with a total volume of 8 MB, 3 x DDR3 ECC memory controllers, 3 x interprocessor communication channels and an I/O channel.
- From the managing microcontroller when power is on; - From the Reset button of the Utility backplane connector; - From the button in the handle-extractor of the CPU module (only for CPC514); Switches (Jumpers) The module is equipped with switches for the following functionalities:...
CPC514 2.3.2 Connector for mezzanine module installation The mezzanine expansion modules can be connected to CPC514 via the XS4 connector. The assignment of the XS4 connector pins for installing the mezzanine module is shown in Table 2-2. Table 2- 2 – Assignment of the XS4 connector pins for installing the mezzanine module 2.3.3 USB, DisplayPort and Ethernet Interfaces...
CPC514 2.3.4 Programming and debugging connectors Table 2 - 3 – Assignment of pins of the XP6 programming and debugging control microcontroller Pin number Signal Name SWDIO Data channel for programming the microcontroller UART_TX Transmission channel of the MK serial port (TTL level)
Ground 2.4 LEDs The front panel of the CPC514 (see Fig. 1 - 7) and CPC514RC (see Fig. 1 - 8) modules is equipped with LED indicators, which are described in Table 2 - 7. Table 2 - 7 – Designations and functions of the LEDS in CPC514/CPC514RC...
The control can be performed using one of the following methods: the “Power Button” on the 19” frame control panel, the extractor’s handle button (only for the CPC514 module), or the ACPI software module of the operating system used. The “Power Button” is connected to the “Utility”...
Page 31
The algorithm for initial activation from a completely disabled state of the system is the same for all cases of CPC514 module application. If power supply does not support management and does not have a +5V “Standby” source, the module starts automatically if there is +12 V. If one of the power sources (both external and internal) fails, the red “SYS”...
Page 32
Fig. 2-4-Algorithm for shutting down the system with the extractor’ handle button, Power Button, or using software via ACPI After executing any of the shutdown algorithms, the system (or only the CPC514 CPU Module) enters the “Software shutdown” state. From this state, switching to the complete disabled state (“Mechanical shutdown”), or to a completely enabled state is possible.
CPC514 3 Installation In order install the CPC514/CPC514RC properly and safely, you should strictly follow the below rules, warnings, and procedures. 3.1 Safety requirements While handling the CPC514/CPC514RC module, you should observe the following safety requirements. The manufacturer is not responsible for any damage resulting from non-compliance with these requirements.
Prior to start the work, make sure that the system is powered off. In order to install the module, follow the steps in the below sections. 3.2.1 Installation of CPC514 In order to install the module, you should perform the following actions: - Carefully insert the module into the desired slot, moving it along the guiderails until it touches the backplane connector.
3.3.1 Removal of CPC514 In order t o remove the CPC514 module, follow the below steps: - Disconnect all interface cables from the module. - Unscrew the retaining screws (upper and lower) on the front panel.
For a prompt reset of loader settings to default parameters and protection of the loader memory chip against program rewriting from the OS, SA2 switch is used. In order to switch the module to the Peripheral Root mode (only when the CPC514/CPC514RC module is installed into peripheral slot), the SA1 switch is used.
4.2 Loader settings reset sequence Sequence of loader settings reset: - Switch off the power; - Remove the CPC514/CPC514RC module from the crate; - Change the SA2.1 operating mode switch to the ON position; - Install the CPC514/CPC514RC module into the crate;...
“Space” key. The following message should appear: BOOT SETUP Fastwel adaptation v0.2 Press command letter, or press 'h' to get help All setup operations are performed in loader’s text menu by serial input of the required parameters upon request of the configuration program.
5.1 Cooling system of СРС514/СРС514RC The CPC514 CPU module generates about 35 watts of heat during its operation. A specially designed copper heatsink is used to maintain the temperature of the processor chip within the acceptable values.
10.8 13.2 The CPC514/CPC514RC module for its operation uses two voltages: +12 V and +5 V “Standby”. The +5 V “Standby” voltage is optional. While using it, you can control the power supply source using the PS_ON # signal in the Utility connector of the backplane.
CPC514 CPC514/CPC514RC is resistant to the following external influencing factors: Table 5 - 2 – External influencing factors Parameter Value Low, °С Changing ambient temperature at relative humidity up to 80 %, non-condensing - for CPC514RC High, °С Low, °С...
1.2 Use of the Fastwel products as well as the objects of intellectual property containing in them, in the ways and for the purposes, not provided by the present user manual and datasheet isn't allowed without preliminary written approval of Fastwel.
Need help?
Do you have a question about the CPC514 and is the answer not in the manual?