TROUBLESHOOTING CHART

SYMPTOMS
1. Float valve
A. Refill tube pushed too far down in overflow pipe.
turns on/off
B. No slack in flapper chain assembly, holding flapper
by itself
off seat.
without
C. Flush valve flapper ball worn, dirty or misaligned
toilet being
with flush valve seat; or seat corroded so flapper
flushed.
will not seal.
2. Float valve
A. Foreign particles lodged under the float valve
continues
seal (located under float valve cap).
to run,
allowing
water to
enter tank.
B. Float valve seal (located under float valve cap)
may be cracked or split.
3. Incorrect
A. Valve float cup does not contain enough water to
provide required ballast.
water level
height.
4. Long or
A. Plugged valve inlet or supply line.
noisy tank
fill cycle.
5. Poor flush. A. Trapway or rim holes are obstructed.
B. Soil pipe or vent is obstructed.
C. Low water level in bowl due to refill tube being
plugged or out of overflow tube.
D. Supply shut-off valve not fully open.
6. Toilet
A. Toilet trapway is obstructed.
overflows.
B. Soil pipe or vent is obstructed.
7. Toilet does
A. Chain is not connected to lift rod or flush valve.
not
activate.
A
1010439-2-
PROBABLE CAUSES
CORRECTIVE ACTION
A. Attach refill tube to overflow pipe above the water
line.
B. Adjust flapper chain assembly for proper slack.
C. Inspect, clean and, if necessary, replace flapper
ball and/or seat.
A. Shut off water supply; remove float valve cap
assembly by rotating 1/8 turn counterclockwise.
Cover uncapped lower valve unit with an inverted
cup (holding it to prevent overspray), and turn
water on and off a few times. Clean float valve
seal surface (located under float valve cap).
Replace float valve cap assembly by engaging
lugs and rotating 1/8 turn clockwise. Turn water
on.
Install filter in supply line to prevent recurring
problems.
B. Replace seal.
A. During fill cycle, hold float under water a few
seconds to allow it to fill with water ballast.
A. Perform Corrective Action 2.A.
A. Unclog trapway; clean rim holes.
B. Clear obstruction from soil pipe or vent.
C. Clean or straighten refill tube; attach refill tube to
overflow tube.
D. Open supply shut-off valve.
A. Use plunger to unclog.
B. Clear obstruction from soil pipe or vent pipe.
A. Reconnect the chain.