Download Print this page
Kohler REVE K-20766T-S Installation Instructions Manual

Kohler REVE K-20766T-S Installation Instructions Manual

Vitreous china floor-standing toilet
Hide thumbs Also See for REVE K-20766T-S:

Advertisement

Quick Links

·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
ORDERING INFORMATION
REVE WF Toilet (HT200 PNE IWT)......................K-20766T-S
Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 200 PNE
In-Wall Tank W/O Frame .............K-78074T-RES
Includes Reve QC Seat ................................K-17183T-CP
REVE WF Toilet (HT300 PNE IWT)......................K-20767T-S
Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 300 PNE
In-Wall Tank W/O Frame .............K-78077T-RES
Includes Reve QC Seat ................................K-17183T-CP
REVE WF Toilet (HT300 MEC IWT) .....................K-20768T-S
Includes Reve Floor Standing Toilet .....................K-5038T
Includes HYDRO-TOWER 300
In-Wall Tank W/O Frame .............K-10611T-RES
Includes Reve QC Seat ................................K-17183T-CP
Maxispace Toilet with Paper Holder ......................K-14042T-L
Maxispace Cabinet with Paper Holder.............K-24902T-L
Reve Floor Standing Toilet ...................................K-5038T
Reve QC Seat...............................................K-17183T-CP
305mm S-Trap ......................................................1249428
Maxispace Toilet with Paper Holder .....................K-14042T-R
Maxispace Cabinet with Paper Holder ............K-24902T-R
Reve Floor Standing Toilet ...................................K-5038T
Reve QC Seat...............................................K-17183T-CP
305mm S-Trap ......................................................1249428
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410
1258187-T01-C
K-25209T-GS/K-21762T-CPS/K-21762T-BNS/K-21763T-CPS/K-21763T-BNS
please leave instructions for the
VITREOUS CHINA FLOOR-STANDING TOILET
K-20766T-S/K-20767T-S/K-20768T-S/K-14042T-L/K-14042T-R
·
·
·
·
(
200
(
300
(
300
(
305mm
(
305mm
2
8
256410
©
Copyright Kohler China Investment Co., Ltd. 2018
-1-
©
REVE
INSTALLATION INSTRUCTIONS
200
)................K-20766T-S
.........................................K-5038T
....................K-78074T-RES
........................................K-17183T-CP
300
)................K-20767T-S
.........................................K-5038T
....................K-78077T-RES
........................................K-17183T-CP
300
)................K-20768T-S
.........................................K-5038T
...........................K-10611T-RES
........................................K-17183T-CP
).....................................K-14042T-L
(
) ...................K-24902T-L
.............................................K-5038T
............................................K-17183T-CP
...........................................1249428
) ....................................K-14042T-R
(
) ..................K-24902T-R
.............................................K-5038T
............................................K-17183T-CP
...........................................1249428
528137
-
:
2018

Advertisement

loading
Need help?

Need help?

Do you have a question about the REVE K-20766T-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler REVE K-20766T-S

  • Page 1 ..........K-17183T-CP 305mm S-Trap ............1249428 305mm ...........1249428 No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410 256410 ©...
  • Page 2 REVE WF Toilet (BEAM M FV) ......K-25209T-GS ) ....K-25209T-GS Includes Bowl ..........K-20725T-GS ............K-20725T-GS Includes BEAM Manual Toilet/Squat ............K-77681K-G Flush Valve........K-77681K-G .........K-17183T-CP Includes REVE Quiet-close Toilet Seat ..K-17183T-CP )....K-21762T-CPS REVE WF Toilet (BEAM SR D/CP)....K-21762T-CPS ............K-21764T-DPS Includes Bowl ..........K-21764T-DPS ........K-30947T-CP Includes BEAM Toilet Sensor (DC) ....K-30947T-CP .........K-17183T-CP Includes REVE Quiet-close Toilet Seat ..K-17183T-CP ) ..K-21762T-BNS...
  • Page 3 TOOLS AND MATERIALS REQUIRED (Not supplied) · · 254mm 254mm (10") adjustable wrench · · 305mm 305mm (12") pipe wrench · · Metal file (file cut) · · Tape measure · · Tubing cutter · · Level · · Hacksaw ·...
  • Page 4 K-14042T-L/K-14042T-R Finished Floor Fig.#1 Kohler reserves the right to change marked dimensions without prior notice. 1258187-T01-C...
  • Page 5 INSTALLATION (WITH CABINET) INSTALLATION (WITH CABINET) MAXISPACE tank with cabinet K-24902T includes the K-24902T installation instruction. INSTALLATION (WITH IN WALL TANK) INSTALLATION (WITH IN WALL TANK) Install The Tank 1. Turn the water supply off before installing the new toilet. 2.
  • Page 6 Install the Toilet 1. Install the waste outlet and water inlet as shown. UNIT mm S.trap P.trap Fig.#3 2. Position the template and align with drain hole or wall. 3. Mark down the position of foot and 2 holes. Foot Hole Drain Hole Fig.#4 4.
  • Page 7 5. Install brackets. Fig.#6 6A. Attach connection pipe (For P trap) 1) Attach inlet pipe which set aside the length to the concealed tank. 2) Attach outlet pipe to the toilet. 3) You may apply some lubricant to help connect smoothly.
  • Page 8 Carefully align and lower backward the bowl. Apply weight to the bowl rim to let the outlet insert into plastic trap. Ensure tank outlet insert into bowl inlet firmly. Apply soap water around rubber seal for easier mounting. Tank outlet Outlet Bowl inlet Plastic Trap...
  • Page 9 8. Carefully thread the screws into the brackets, until toilet is secure. Alternately tighten left and right sides to prevent pulling the toilet off center. Install cap to cover screw. Do not overtighten. Bushing Screw Fig.#10 9. Apply caulk around . Fig.#11 10.
  • Page 10 Fill Float With Ballast Test flush the toilet. Check all connections for leakage for several days. Fig.#13 SYMPTOMS PROBABLE CAUSES CORRECTIVE ACTION 1.Dual flush fail. A. Push button do not touch seat. A. Operate push button correctly. 2. Fill valve continues to A.
  • Page 11 1258187-T01-C -11-...
  • Page 12 CAUTION: Don t use any cement while installing the toilet. Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement. WARNING: Risk of product damage. Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel.
  • Page 13: Before You Begin

    G1 Screw Die Machine 1.5mm ROUGHING-IN Reference Value UNIT : mm G1" Fig.1 Kohler reserves the right to change marked dimensions without prior notice. KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD, JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436 200436 ©...
  • Page 14: Specifications

    SPECIFICATIONS K-77681K-G/K-77682K-G/K-77683K-G Flush Volume 4.5L, 6L, 3.5L Minimum Water Pressure 0.05mpa(Dynamic Pressure 0.75mpa(Static Pressure Maximum Water Pressure Water Temperature 1 ~50 Note: Only K-77682K-G(6L)can match Bardon squat(K-20441T/K-20441T/K-20441T) K-77682K-G(6L) (K-20441T/K-20441T/K-20441T) INSTALLATION 1. Drill wall Draw lines and drill the wall according to Fig.2. The horizontal distance between the bottom of plate and the surface of squat 1200mm pan is advised to be 1200mm, and the horizontal distance...
  • Page 15 3. Cut box Cut the excessive part of the box as shown. Fig.4 4. Install valve assembly Fix valve assembly onto inlet and outlet pipes with wrench as shown in Fig.5. Fix onto inlet pipe · · Process inlet pipe thread and fix inlet pipe connector. ·...
  • Page 16 5. Cut and fix tile Cut tiles as shown in Fig.6. 124mm-130mm Fig.6 6. Fix bottom board · · Tighten the 6 screws on the bottom board. · Cut the rod connector according to the depth into the tile · (17.8 );...
  • Page 17 7. Fix faceplate · · Put the faceplate onto the bottom board. · · Pull the faceplate downwards. · · Tighten the rod with L wrench. Note: When removing the faceplate, unscrew the screw 3mm out and push the faceplate 3.5mm upwards to remove it. 3.5mm Snap Pull...