Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent
gases into the atmosphere.
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
To fix the fluorinated greenhouse gases label
1
Fill in the label as follows:
Contains fluorinated greenhouse gases
1
6
GWP: XXX
2
2
1
1
+
2
GWP × kg
1000
1 From the multilingual fluorinated greenhouse gases label
peal off the applicable language and stick it on top of 1.
2 Factory refrigerant charge: see unit name plate
3 Additional refrigerant amount charged
4 Total refrigerant charge
5 Greenhouse gas emissions of the total refrigerant charge
expressed as tonnes CO
6 GWP = Global warming potential
CAUTION
In Europe, the greenhouse gas emissions of the total refrigerant
charge in the system (expressed as tonnes CO
to determine the maintenance intervals. Follow the applicable
legislation.
Formula to calculate the greenhouse gas emissions: GWP value
of the refrigerant × Total refrigerant charge [in kg] / 1000
2
The filled-in label must be adhered in the proximity of the
product charging port (e.g. onto the inside of the service cover).
WARNING
Always recover the refrigerant. Do NOT release them directly into the
environment. Use a vacuum pump to evacuate the installation.
[DESIGN PRESSURE]
Since design pressure is 4.0 MPa or 40 bar, the wall thickness of pipes
should be more carefully selected in accordance with the relevant local
and national regulations.

1-3 Disposal Requirements

Dismantling of the unit, treatment of the refrigerant, oil and eventual
other parts, should be done in accordance with the relevant local and
national regulations.
2.

BEFORE INSTALLATION

CAUTION
• When installing the indoor unit, refer to the installation manual pro-
vided for the indoor unit.
• Optional accessories are required for the installation of the prod-
uct. Refer to the information on optional accessory.
Installation manual
3
1
kg
2
=
kg
3
=
4
kg
=
=
tCO
eq
5
2
-equivalent
2
-equivalent) is used
2

2-1 Standard Supplied Accessories

The following accessories are included. The storage location of the
accessories is shown in the figure.
Note
Do not throw away any of the accessories until installation is complete.
Gas side accessory pipe
Name
(1)
Quantity
1 pc.
Shape
Liquid side accessory
Name
pipe (1)
Quantity
1 pc.
Shape
Liquid side
Name
accessory
pipe (3)
Quantity
1 pc.
Shape

2-2 Example of System Configuration

Name
Outdoor unit
Shape
Name
Air-conditioner
Shape
Indoor unit
Freezer
Name
Blower coil Showcase
Shape
Gas side accessory pipe
(2)
1 pc.
Liquid side accessory
pipe (2)
1 pc.
Liquid side
accessory
Others
pipe (4)
1 pc.
1 pc. about each item
• Operation manual
• Installation manual
• Fluorinated green-
house gas label
• Multilingual fluori-
nated greenhouse
gas label
Booster unit
Indoor unit
Refrigeration
Blower coil
Showcase
Remote
Control
Warning
controller
panel
panel
(for air-
(Defrost)
conditioner)
LRYEQ16A7Y1
CONVENI-PACK
4P448939-1A – 2016.07

Hide quick links: