b. Multifeeder Feeding
The standard near side registration on a DIERCT copy of the test sheet is 10.0 ±2 mm.
Loosen the screw, and adjust the multifeeder side guide by sliding it. Then, tighten the screw.
CHAPTER 2 STANDARDS AND ADJUSTMENT
0
2
4
6
8
10 ±2 mm
10
Figure 2-6
Side guide
Figure 2-7
Screw
2-3