Kongsberg Simrad RA83 Instruction Manual page 143

Hide thumbs Also See for Simrad RA83:
Table of Contents

Advertisement

Chapter 8
Trouble Shooting And On Board Servicing
 
Tuning meter is faulty
 
 
 
 
 
 
 
Automatic tuning does
 
not function
 
 
 
 
 
 
 
 
 
 
 
 
No picture
 
 
 
Is the error message "MAGNETRON
 
CURRENT ABNORMAL" shown?
Does the MIC monitor voltage lies within
30 – 70 mV?
Is the video signal connection normal in
the Antenna Cable?
Main Logic PCB or LCD module is faulty.
8-16
Is the tuning voltage on J1-3
(IF PCB) about 2 V?
Y
Y
Perform
the
procedure
automatic tuning set up
Does the automatic tuning function
become normal?
Y
Finished
N
Y
Y
RA83/84/85/93/94/95 Series
N
IF PCB is faulty.
Check for the cable connection
between IF PCB (J1) and
Modulator PCB.
for
N
IF PCB is faulty.  
Y
The magnetron is faulty.
N
MIC module is faulty.
N
Repair a faulty connection.
Operation Manual
93142105-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents