Chapter 8
Trouble Shooting And On Board Servicing
(3) IEC 61162-1 Interface
 
Is the serial data (IEC
 
61162-1) properly received
 
via DATA 1,2 and 3
connector and displayed?
 
Press and hold the MODE
 
key and turn the radar on.
This allows maintenance
 
operation. On stand-by
mode, press MENU key
 
until SERIAL LINE
 
MONITOR displayed on the
screen. Check received
 
data on the screen.
 
 
Y
 
 
Are the incoming serial
data from DATA 1, 2, and 3
 
acceptable format?
 
Y
 
 
Press and hold the MODE key and turn the
 
radar on. This allows protected SYSTEM
 
SETUP MENU operation. Set the following
items to IEC 61162-1 format.
 
SERIAL GPS, SERIAL COMPASS and
 
SERIAL LOG format
 
 
Y
 
 
 
 
 
 
 
 
 
 
 
 
 
8-10
N
Is
signal
correct?
Y
Is the input signal level at the
following points in Main Logic
PCB 4V or more?
J712-4 and 5 pins
J713-4 and 5 pins
J714-4 and 5 pins
Y
N
Change the format in the menu.
N
RA83/84/85/93/94/95 Series
N
polarity
Correct the polarity.
Signal level is not sufficient.
Take necessary measures to
receive properly rated signal.
Main Logic PCB is faulty.
Reset the serial data format to
IEC 61162-1.
Main Logic PCB is faulty.
Operation Manual
93142105-02