Download Print this page

Samsung WMN-M10E Cautions When Installing page 8

No gap wall mount

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Standard Installation Requirements by Wall Type
[ Check the wall type before installing.
• Can only be mounted on a concrete or interior wall of sufficient thickness.
See the diagrams below.
Min. 50 mm
When there is
reinforcing wood
such as MDF or PW
(plywood)
Min. 10 mm
MDF, PW (plywood)
Min. 25
mm
MDF, PW (plywood)
(excluding gypsum
board thickness)
Min. 25
mm
Hybrid concrete
walls
(excluding
gypsum board
thickness)
– Be sure to check the type and condition of the wall you will
install on.
– Materials to be used may differ depending on wall type.
Choose materials based on the specifications below.
– You do not need to use all the supplied screws. However,
you must use at least 4 screws.
– You must use screws in the two locations marked as A.
– Choose at least 2 of the parts marked B to assemble
depending on surroundings.
Min. 30 mm
Min. 50
mm
MDF, PW (plywood)
Min. 10 mm
MDF, PW (plywood)
Min. 30 mm
Concrete
Artwall
Min. 10 mm
MDF, PW (plywood)
• Note
MDF = Medium Density Fiberboard
PW = Plywood
- English 8 -
• First, check the status of the wall
(type, thickness, flatness).
TV
Wall
Surface
If the wall surface is not completely
flat, gaps may form after
installation.

Advertisement

loading