Kohler K-1109 Installation Manual page 12

Bath whirlpool
Hide thumbs Also See for K-1109:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting Procedure (cont.)
Symptoms
2. Motor starts, not all jets are
functioning.
3.
Whirlpool stops automatically
before 18 minutes.
4. Noisy operation.
5.
Heater does not operate. ("H"
models only)
1012295-2-D
Probable Causes
D. Motor/pump does not work.
A. Jet is closed.
B. Jets are blocked.
A. The GFCI or ELCB trips.
B. Suction blocked.
C. Jets are blocked.
D. Motor overheated and
protection device activated.
A. Pump banding straps have not
been cut. (Models with support
blocks only.)
A. No power to heater.
B. Water temperature exceeds
104° F (40° C).
C. Heater does not work.
12
Recommended Action
D. Rebuild or replace
motor/pump.
A. Rotate jet trim ring
counterclockwise to open.
B. Remove blockage.
A. Identify source of fault, and
correct.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
blockage and allow motor to
cool.
A. Cut pump banding straps with
tin snips.
A. Reset the GFCI or ELCB.
B. Allow water to cool and heater
will reengage.
C. Replace heater.
Kohler Co.

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-1151K-1357

Table of Contents