Nokia Customer Care
Figure 31
shows the Rx VHF LO test points.
Table 12
gives the description and values for the test points as shown in
Test
Point
1
2
3
Tx UHF LO
There are two fixed LOs: 3296.16~3395.88 MHz for Cell band and 3700~3819.90 MHz
for PCS band. This is the first LO for up-conversion. Monitor the control voltage at
C7014. At this control voltage, the N7000 LO is locked and should be between 1.2 and
1.8 VDC.
ISSUE 1 08/2005
1
Figure 31: Rx VHF LO test points
Table 12: Rx VHF LO Test Points
Description
RX LO lock voltage
VR7
VR5
©2005 Nokia Corporation
2125/2125i/2126/2126i/2128i (RH-71)
RF Description and Troubleshooting
2
3
Value
1.2 to 1.7 VDC
2.8V
2.8V
Company Confidential
Figure
31.
Page 41