Without Noise Suppressor (for the U.S.A.)
Internal Wire
(brown) [6] <6>
Internal Wire (blue)
[26] <26>
1-5. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct a dielectric
strength test.
Insulation Resistance: 7 MΩ or more with DC 500 V megohm tester
Dielectric:Strength:
1-6. No-Load Current Value
After no-load operation for 30 minutes, the current value should be as follows.
Voltage
Current (A) Max.
Tab Terminal (brown) [27] <27>
Tab Terminal (blue) [7] <7>
AC 4,000 V/1 min.
with no abnormalities
(and for 110 V U.K. products)
AC 2,500 V/1 min.
with no abnormalities
110 V
115 V
1.15 A
1.10 A
Slide Switch [22] <22>
1
Pillar Terminal [21] <21>
Fig. 12
220 V - 240 V
110 V - 127 V
120 V
127 V
1.05 A
0.99 A
−#6 −
2
Black
White
220 V
230 V
0.57 A
0.55 A
Cord
240 V
0.53 A

Advertisement

loading

This manual is also suitable for:

Sv 12sf