Panasonic EYFGA1N Operating Instructions Manual page 33

Hide thumbs Also See for EYFGA1N:
Table of Contents

Advertisement

Available languages

Available languages

RPM
0
00
75
750
45
450
15
150
4. Press the OK button to accept the select-
ed speed adjustment setting.
• The control panel will stop flashing and
light up.
CAUTION:
• You must press the OK button in order
for the selected setting to take effect.
• Be sure to verify the new value after
changing the setting. (See page 5.)
Auto downshift function
• By having the tool operate at high speed
at the start of the tightening process then
shifting to low speed operation just before
the tightener becomes flush the auto
downshift function increases tightening
speed while maintaining accuracy. When
Auto Downshift is enabled it downshifts
to a low speed of 00 RPM at the time
programmed with the remote control.
1. Set the tool to setting configuration mode.
(See page .)
. Press the D button twice.
• The auto downshift function setting value
will be displayed.
. Press the
and
time as desired.
Operation
Display
4. Press the OK button to accept the new
setting.
NOTE:
• The speed at the start of tightening
operation is set with the speed adjust-
ment function.
GA1
GA
GA
Setting not
available
Setting
available
buttons to change the
Seconds
0
 seconds
1
0.1 seconds
0
OFF
Cross thread reduction function
• The tool runs in reverse approximately 60
degrees before running forward to assist in
the alignment of the threads to help reduce
cross threads.
1. Set the tool to setting configuration mode.
(See page .)
. Press the D button once.
• The cross thread reduction function set-
ting value will be displayed.
. Press the
setting to ON or OFF.
Display
R0
R1
4. Press the OK button to accept the ON or
OFF setting.
Rundown error detecting function
• The rundown error detecting function causes
a red indicator to flash if work ends more
quickly than a set time, for example due
to retightening of a previously tightened
fastener or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page .)
. Press the B button twice.
• The rundown error detecting function
setting value will be displayed.
. Press the
time as desired.
Operation
4. Press the OK button to accept the new
setting.
• When the cross thread reduction func-
tion is ON, the set time will be counted
after the tool operates in reverse for
approximately 60°.
Maintenance interval alarm function
• The maintenance interval alarm function
locks the tool so that it can no longer be
operated once a set number of tightening
operations has been performed. This
function is convenient when regularly
inspecting tool performance, for example.
-  -
and
buttons to change the
Function
OFF
ON
and
buttons to change the
Display
Seconds
0
 seconds
1
0.1 seconds
0
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eyfga1nrEyfga2nEyfga2nrEyfga3nEyfga3nr

Table of Contents