Electrolux EXM18HV1W Installation Manual page 19

Split type room air conditioner
Hide thumbs Also See for EXM18HV1W:
Table of Contents

Advertisement

Available languages

Available languages

installation of Outdoor
Electric Wires
1 Remove the handle on the right side plate of
outdoor unit by loosening the screw.
EXM18HV1WE
EXM24HV1WE
2 Take off wire cable clamp. Connect and
screw the power connection cable and signal
control wire (for heap pump model only) onto
the terminal block following corresponding
identification numbers and colors on the
terminal blocks of indoor and outdoor units.
3 To prevent water from entering, make a trap
("U") in the connection wires (see page 16).
4 Wrap wires that are not connected with
insulating tape so that they do not touch any
electrical or metal parts.
5 Fix the power connection wires with wire
clamps.
6 Reinstall the handle.
19