Summary of Contents for Sharp UA-HG60E

  • Page 1 OPERATION MANUAL UA-HG50E UA-HG40E "Plasmacluster" and "Device of a cluster of grapes" are trademarks of Sharp Corporation. Free standing Type * The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm which is measured around the center of a room with the “high-density plasmacluster 7000”...
  • Page 2 INTELLIGENT MODE When a person or pet is in the sensory area* (*4: Ref.E-5) (UA-HG60E / UA-HG50E) • When there is little movement of a person or pet (example: when sleeping), automatically switches to quiet air fl ow. 6 sensors sensing 7 •...
  • Page 3: Table Of Contents

    E-16 ......SPECIFICATIONS E-17 ........Pre-Filter Thank you for purchasing this SHARP Air Purifi er. Please read this manual carefully before using the air purifi er. After reading, keep the manual in a convenient location for future reference. NOTE •...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Always follow basic safety precautions • Only a Sharp Authorized Service Centre when using electrical appliances, should service this air purifi er. Contact the including the following: nearest Service Centre for any problems, adjustments, or repairs. • Do not operate the unit in rooms where WARNING –...
  • Page 5: Installation Guidelines

    • Always operate the unit in an upright • Do not scrub the Back Panel hard during position. its maintenance. • When moving the unit, use the handles on INSTALLATION GUIDELINES both sides. Do not move the unit when it is in •...
  • Page 6: Part Names

    PART NAMES FRONT 20° 20° Handle (2 Locations) Sensor (Internal) Temperature / Humidity / Odour* (*UA-HG60E / UA-HG50E) Air Outlet (Front) Caster Stopper (Right & Left) Operation Panel To Lock a caster stopper (Right & Left) Front Louver (Adjustable) Locked...
  • Page 7: Operation Panel

    Humidity / Temperature Monitor (Ref.E-9, E-10) Indicates the approximate humidity level or tem- perature in the room. The humidity setting cannot be Odour Light (White) (UA-HG60E / UA-HG50E) adjusted. Indicates the Odour Sensor detects odours. Humidity 20% to 90% is displayed. 90% or...
  • Page 8: Preparation

    • When replacing the fi lter, making a memo of the start of use date is recommended. OPERATION START/STOP INTELLIGENT MODE (UA-HG60E / UA-HG50E) The fan speed is automatically controlled depending on the 7 START STOP detection. (Ref. E-1) CLEAN ION SHOWER MODE...
  • Page 9: Plasmacluster Ion Spot Mode

    PLASMACLUSTER ION HUMIDIFICATION SETTING SPOT MODE REFILLING THE WATER TANK Use this mode when you want to remove adhering odour, germs, and other substances from cloths, sofas and curtains. Remove the Water Tank. Adjust Front Louver manually. NOTE Fill the Water Tank •...
  • Page 10: On Timer

    ON TIMER OFF TIMER Select the length of time you want. The unit automatically Select the length of time you want. The unit automatically stops once the selected time is reached. starts once the selected time is passes. (with the unit ON) (with the unit OFF) 1hour 2hour...
  • Page 11: Selecting Display

    SELECTING DISPLAY PLASMACLUSTER ION ON/OFF When the Plasmacluster function is ON, the Plasmacluster Ion light on the Front Display is on. (Ref.E-6) (with the unit ON) more more 3 sec. 3 sec. Humidity Temperature Wattage The beeping sound of Patrolling Function is set to "Off" at the default. You can change it to "On" or "Cancel Patrolling Function".
  • Page 12: How To Change Various Settings

    HOW TO CHANGE VARIOUS SETTINGS You can change the functions in the "Type of setting" table in the following. Select "Setting number" from the table Turn the unit power OFF. in the following. Forward Reverse more 3 sec. Select "Function number" from the table in the following.
  • Page 13 Adjusting Sensor Sensitivity (F4-F7) Light Sensor Dust(sensitive) Sensor Standard (default) Odour Sensor High (UA-HG60E / UA-HG50E) ON(Standard sensing time ) (default) Motion Sensor (UA-HG60E / UA-HG50E) You can set the time until the Mo- ON(Longer sensing time) tion Sensor detects that no one is in the room .
  • Page 14: Care And Maintenance

    CARE AND MAINTENANCE FILTER INDICATOR WATER TANK The fi lter reset Indicator light will turn on after approximately Rinse the inside 720 hours operating. (30 days × 24 hours =720 hours) with water. RESET NOTE How to clean hard to remove dirt. Clean the inside of the Water Tank with more than...
  • Page 15: Humidifying Filter And Tray

    HUMIDIFYING FILTER AND TRAY HOW TO REMOVE THE HUMIDIFYING FILTER AND TRAY. HOW TO ATTACH THE Gray White HUMIDIFYING FILTER AND TRAY. After maintenance, correctly reattach the parts. Humidifying Filter Humidifying Tray Remove the Humidifying Tray Cover. Rinse with plenty of water. Tray Cover Rinse with plenty of water.
  • Page 16: Hepa Filter / Deodorizing Filter

    Both surfaces can be main- Consult your dealer when purchasing a replacement tained. fi lter. The fi lter may be broken if being too much power Replacement UA-HG60E UA-HG50E UA-HG40E is applied on it, so please Filter handle it with care. HEPA Filter...
  • Page 17: Troubleshooting

    • The room temperature and humidity is high. We recommend that you drink some water or lower the room temperature. (Ref. E-10) ERROR DISPLAY If error occurs repeatedly, contact the Sharp Service Centre. DIGITAL INDICATION REMEDY Make sure that the Humidifying Filter and Humidifying Tray are properly installed, and then turn the power to ON again.
  • Page 18: Specifications

    SPECIFICATIONS Model UA-HG60E UA-HG50E UA-HG40E Power supply 220-240 V 50-60 Hz Fan Speed Adjustment Fan Speed (m /hour) CLEAN Rated Power (W) Noise Level (dBA) Fan Speed (m /hour) CLEAN AIR Rated Power (W) & Noise Level (dBA) HUMIDIFY Humidifi cation...