Troubleshooting - What to check when problems occur:
PROBLEM
The unit frosts up.
Water is leaking out the back of the
unit.
Ice cubes sticking together
Noise during operation
No ice
Not enough ice
Water leaks into ice bucket.
12
POSSIBLE CAUSE
High ambient temperatures or
humidity
Unit is a manual defrost unit.
Door gasket not sealing properly
Water supply connection leaking
Infrequent use of cubes
Copper water supply tubing
contacting internal components
Certain sounds are normal.
Bin arm locked in upright position
No water to unit
Ice cube size too large
Dirty condenser coils
Airflow to front grille blocked
Temperature not set cold enough
Water level set too high
ADA15IM
ADA SERIES
REMEDY
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Model BI2115 is a manual defrost unit (See
MAINTENANCE; DEFROSTING).
Adjust door (See MAINTENANCE; DOOR ALIGNMENT
CHECK AND ADJUSTMENT and DOOR REVERSAL).
Tighten fitting as required.
Break apart cubes.
Carefully bend tubing away from cabinet and
components.
Soft sounds from the fan and ice dropping from the ice
maker will be heard.
Lower bin arm.
Turn on water or contact plumber.
Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUSTMENT).
Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Airflow must not be obstructed to front grille (See
OPERATION).
Set control to cooler setting (See OPERATION). Allow 24
hours for temperature to stabilize (See OPERATION).
Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUSTMENT).