Watts OneFlow OF210-1 Installation, Operation And Maintenance Manual page 4

Anti-scale systems chemical-free, salt-free scale prevention
Table of Contents

Advertisement

Available languages

Available languages

Installation Drawings & Dimensions
B
A
Clearance
Ordering
Model
Code
in.
OF210-1
0002151
14
OF220-2
0002152
24
OF240-4
0002153
25
* The overall height and the height of the inlet fitting varies due to material variations
and assembly tolerances. Please allow additional clearances above the system for
making connections.
Peak Flow Rates — Weights
Model
OF210-1
*Maximum Flow
1 gpm 3.8 lpm
Dry Weight
9 lbs. 4 kgs.
Service Weight
17 lbs. 7.7 kgs.
*Exceeding maximum flow can reduce effectiveness and void warranty.
Mounted to secure wall on studs or wall panel –
Do not mount to unsupported sheet-rock or
gypsum board.
OF240-4 system, once full is heavy and must be
mounted using 5/16" hardware.
Water filtration unit must be installed on the
cold water supply only.
Dimensions
A*
B
cm
in.
cm
37
5
15
1
3
2
4
62
5
15
1
3
2
4
64
8
22
1
5
8
8
OF220-2
2 gpm 7.6 lpm
14 lbs. 6.4 kgs.
29 lbs. 13.2 kgs.
C
D
in.
cm
in.
cm
12
32
5
15
3
3
4
4
12
32
5
15
3
3
4
4
17
45
12
31
7
1
8
4
OF240-4
4 gpm 15.1 lpm
31 lbs. 14 kgs.
59 lbs. 26.8 kgs.
4
C
D
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oneflow of220-2Oneflow of240-4

Table of Contents