V1.0
12V DC 3-WAY, 2-POSITION DIRECTIONAL CONTROL VALVE
SPECIFICATIONS
Rated Input Flow
6 GPM
Maximum Pressure
3,000 PSI
Internal Leakage
5 cu. in./min. @ 3,000
PSI
Filtration
10 Micron minimum
Requirement
Temperature Range
-30°C to 120°C
(-22°F to 250°F)
Power Consumption
20W (1.7 A)
Port Size
8 ORB
INTRODUCTION
This valve is used to divert hydraulic oil flow
entering Port 2 of the valve from one hydraulic
circuit to a separate hydraulic circuit when
power is applied to the coil. Oil Flows to Port 1
when the coil is OFF. Energizing the coil
switches the hydraulic oil flow to Port 3.
Please read and understand all instructions before use. Retain this manual for future reference.
SAFETY
WARNING! Read and understand all
instructions before using this device. The
operator must follow basic precautions to
reduce the risk of personal injury and/or
damage to the equipment.
Keep this manual for safety warnings,
precautions, operating or inspection and
maintenance instructions.
1.
Use the correct device for the job. This
device was designed for a specific function.
Do not modify or alter this device or use it
for an unintended purpose.
2.
Operate in a safe work environment. Keep
your work area clean, well-lit and free of
distractions.
3.
Do not operate any device when tired or
under the influence of drugs, alcohol or
medications.
4.
Always wear impact safety goggles that
provide front and side protection for the eyes.
Eye protection equipment should comply
with CSA Z94.3-07 or ANSI Z87.1 standards
based on the type of work performed.
5.
Wear protective clothing designed for the
work environment and device.
6.
Consult the safety precautions for your
hydraulic system when installing and
operating this valve.
UNPACKING
WARNING! Do not operate the device if any
part is missing. Replace the missing part before
operating. Failure to do so could result in a
malfunction and personal injury.
Remove the parts and accessories from the
packaging and inspect for damage. Make sure
that all items in the parts list are included.
Contents:
Solenoid Valve
ASSEMBLY
WIRING
1.
Connect positive wire (+)
to terminal 1.
2.
Connect negative wire (-)
to terminal 2.
OPERATION
Hydraulic oil flows from
Port 2 to Port 1 when the
coil is not energized.
Applying power to the
coil activates the valve
and the hydraulic oil
from Port 2 is diverted
to Port 3.
8688848

Advertisement

loading

Summary of Contents for pro.point 8688848

  • Page 1 V1.0 8688848 12V DC 3-WAY, 2-POSITION DIRECTIONAL CONTROL VALVE SPECIFICATIONS SAFETY UNPACKING WARNING! Read and understand all WARNING! Do not operate the device if any Rated Input Flow 6 GPM instructions before using this device. The part is missing. Replace the missing part before...
  • Page 2 V 1,0 8688848 SOUPAPE DE COMMANDE DIRECTIONNELLE DE 12 V C.C., À 3 VOIES ET À 2 POSITIONS SÉCURITÉ DÉBALLAGE SPÉCIFICATIONS AVERTISSEMENT ! Veuillez lire et AVERTISSEMENT ! Ne faites pas fonctionner Débit d’entrée 6 gal/min comprendre toutes les instructions avant l'appareil si des pièces sont manquantes.