ULTRASONIC FLOWMETER
SONIX 30D
INSTRUCTION FOR ASSEMBLY AND OPERATING
SONIX
®
Industrial Electronic Devices
ul. Leopolda Lisa-Kuli 12, 05-270 Marki, Poland
phone:+4822-7811133, fax: +4822-7811644
www.sonix.com.pl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30D and is the answer not in the manual?

Questions and answers

Summary of Contents for SONIX 30D

  • Page 1 ULTRASONIC FLOWMETER SONIX 30D INSTRUCTION FOR ASSEMBLY AND OPERATING SONIX ® Industrial Electronic Devices ul. Leopolda Lisa-Kuli 12, 05-270 Marki, Poland phone:+4822-7811133, fax: +4822-7811644 www.sonix.com.pl...
  • Page 2: Table Of Contents

    E2 Diagnostic screen........................10 E3 Diagnostic messages........................ 11 E4 Working time Time of correct work.................... 11 E5 Serial number Program version Checksums................11 E6 SONIX phone number......................11 E7 Access code..........................11 User functions screens........................11 F1 Range flow Qp........................... 11 F2 Setting the thresholds........................
  • Page 3: General Informations On Safety

    - SONIX reserves the right to change the product in order to increase its utility values or adjust it to current regulations. Such changes may not be taken into account in the current version of the manual.
  • Page 4: Introduction

    Instructions for Assembly and Operating SONIX 30D INTRODUCTION The SONIX 30D flowmeter consists of a flow sensor with 2 or 6 ultrasonic Component probes and a measuring transducer connected together with probes cables. parts The flow sensor is available in three versions: 1.
  • Page 5: Assembly

    Instructions for Assembly and Operating SONIX 30D ASSEMBLY The choice of location and manner of the assembly of the flow sensor Mechanical decides on the metrological properties of the device. assembly of the The following conditions must be met in order to provide correct...
  • Page 6: Recommendations For The Flow Sensor Assembly

    Instructions for Assembly and Operating SONIX 30D Recommendations Choose the longest available straight section of the pipeline. Install the ➢ sensor with probes on the 3/4 of its length starting from the inflow. for the flow sensor Make sure that in the selected spot the liquid will not be aerated and air or ➢...
  • Page 7: User's Preparation For Assembly

    Choice of the measuring spot on the pipeline and choice of measuring ➢ transducer location. The standard length of probes cables is 6 x 5m. In preparation for case of doubts, it is recommended to consult a SONIX representative. assembly Preparation of the pipeline for assembly: ➢...
  • Page 8: Electrical Connections

    Instructions for Assembly and Operating SONIX 30D Power supply conection - Protective earth conductor up to 2.5mm - Protective earth conductor up to 2.5mm - Protective earth conductor up to 2.5mm (13 AWG) has to be connected to terminal terminal...
  • Page 9: Operating

    Instructions for Assembly and Operating SONIX 30D Flowmeter SONIX 30D CABLES SHIELDS PROBES A, B, C bleck PROBE A CABLE white black PROBE B CABLE white black PROBE C CABLE white black PROBE D CABLE white black PROBE E CABLE...
  • Page 10: Descriptions Of The Menu

    Instructions for Assembly and Operating SONIX 30D Descriptions of the menu Basic main screens Button Upper line Bottom line Current flow Total volume Right Upper threshold Lower threshold Right Diagnostic data Diagnostic message Right Diagnostic messages Diagnostic messages Left Working time...
  • Page 11: E3 Diagnostic Messages

    7 or 8 digits factory number, L – checksum saved after verification 4 digits program version, CRC – current checksum Serial number Program version Checksums Logo of the SONIX company. Phone number of SONIX’s service. E6 SONIX phone number 4 digits access to user funktions. Default value: 1111. Access code...
  • Page 12: F2 Setting The Thresholds

    Instructions for Assembly and Operating SONIX 30D Programming of the lower and upper flow threshold in m /h or t/h. F2 Setting the Password chan thresholds Change of output current: 0-20mA or 4-20mA F3 Change of the Programming the characteristics of the current output: current output 1 –...
  • Page 13: Errors

    “measurement OK” - the measurements are done correctly. Servicing Service of the flowmeter is performed only by the SONIX servicing team. Service includes: – supervision over the assembly and start-up of the flowmeter –...
  • Page 14: The Series Rs485 Output

    Instructions for Assembly and Operating SONIX 30D THE SERIES RS485 OUTPUT Protocol The MODBUS RTU protocol of series transmission is compliant with the current specification available at www.modbus.org Transmission speeds: description 1200, 2400, 4800 or 9600 B/s. Addresses of the devices: 1 ...255.
  • Page 15: List Of Registers

    Instructions for Assembly and Operating SONIX 30D List of registers Register Variable Name of the variable type float LO Flow m3/h long int HI Positive volume m3 Positive volume l float LO Liquid speed m/s errors 1... 16 long int...
  • Page 16: Guarantee Certificate

    (e.g. the probes’ surface covering with deposit, presence of air in the pipeline, exceeding the allowed temperature limit for the ultrasound probes etc.). Name of the product: ULTRASOUND FLOWMETER, type: SONIX 30D Purchasing company:..................

Table of Contents