SONIX 10D Instructions For Assembly Operation

Ultrasonic flowmeter

Advertisement

Quick Links

ULTRASONIC FLOWMETER
SONIX 10D
INSTRUCTION FOR ASSEMBLY AND OPERATING
SONIX
®
Industrial Electronic Devices
ul. Leopolda Lisa-Kuli 12, 05-270 Marki, Poland
phone:+4822-7811133, fax: +4822-7811644
www.sonix.com.pl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10D and is the answer not in the manual?

Questions and answers

Summary of Contents for SONIX 10D

  • Page 1 ULTRASONIC FLOWMETER SONIX 10D INSTRUCTION FOR ASSEMBLY AND OPERATING SONIX ® Industrial Electronic Devices ul. Leopolda Lisa-Kuli 12, 05-270 Marki, Poland phone:+4822-7811133, fax: +4822-7811644 www.sonix.com.pl...
  • Page 2: Table Of Contents

    Instructions for Assembly and Operating SONIX 10D Contents GENERAL INFORMATIONS ON SAFETY....................3 Introduction............................3 Symbols..............................3 Disclaimer.............................. 3 INTRODUCTION............................4 Component parts ..........................4 List of supplied elements........................5 Purpose ..............................5 Basic technical data ..........................5 ASSEMBLY............................6 Mechanical assembly of the flow sensor ....................6...
  • Page 3: General Informations On Safety

    - SONIX reserves the right to change the product in order to increase its utility values or adjust it to current regulations. Such changes may not be taken into account in the current version of the manual.
  • Page 4: Introduction

    Instructions for Assembly and Operating SONIX 10D INTRODUCTION The SONIX 10D flowmeter consists of a flow sensor and a measuring Component transducer connected together with probes cables. The flow sensor is parts available in three versions: 1. An U-shaped section ended with flanges or a screw thread (DN15...40)
  • Page 5: List Of Supplied Elements

    - a flow sensor with two or four ultrasound probes including cables - Instructions for Assembly and Operating and a Guarantee Certificate - Calibration certificate for the flowmeters calibrated in the SONIX company flow stand Measurement of flow intensity and summing the volume of flowing liquids in Purpose closed, fully filled pipelines.
  • Page 6: Assembly

    Access eye for removing solid impurities In the majority of cases, straight sections of the following lengths are Length of sufficient: straight - Inlet: 10D sections of the - Outlet: 3D Two- or more surface spatial configurations of the pipeline, the pump, not pipeline entirely closed valves, side inlets etc.
  • Page 7: Recommendations For The Flow Sensor Assembly

    Instructions for Assembly and Operating SONIX 10D Recommendations Choose the longest available straight section of the pipeline. Install the ➢ sensor with probes on the 3/4 of its length starting from the inflow. for the flow sensor Make sure that in the selected spot the liquid will not be aerated and air or ➢...
  • Page 8: User's Preparation For Assembly

    Choice of the measuring spot on the pipeline and choice of measuring ➢ transducer location. The standard length of probes cables is 4 x 5m. In preparation for case of doubts, it is recommended to consult a SONIX representative. assembly Preparation of the pipeline for assembly: ➢...
  • Page 9: Electrical Connections

    Instructions for Assembly and Operating SONIX 10D Power supply conection - Protective earth conductor up to 2.5mm - Protective earth conductor up to 2.5mm - Protective earth conductor up to 2.5mm (13 AWG) has to be connected to terminal terminal...
  • Page 10: Probe's Cable Correct Ending

    Instructions for Assembly and Operating SONIX 10D Probe's cable correct 25 mm ending 55 mm OPERATING General The user communicates with the device via the LCD 2 x 1 6 characters display using two push buttons for choice of functions or parameters. The...
  • Page 11: E0 Flow Volume

    Time of correct work means the number of hours without signaling errors of Working time group I or II. Time of correct work Logo of the SONIX company. Factory number of the flowmeter. Phone number of SONIX’s service. SONIX Using the user’s functions does not influence flow measurement and volume User’s functions counting done at the same time by the flowmeter.
  • Page 12: Password Change

    The counter may also be operated by the RS485 series link (see Protocol of series transmission). Servicing Service of the flowmeter is performed only by the SONIX servicing team.
  • Page 13: Errors

    Instructions for Assembly and Operating SONIX 10D ERRORS Operating flowmeters errors are divided into two groups: General I. Errors causing incorrect measurement and requiring immediate servicing. information The occurrence of such error is signaled by periodical blanking of the display every 0.3s. All outputs return to non-active states. Volume counting and the counter of correct work are blocked.
  • Page 14: The Series Rs485 Output

    2.5V voltage. (see electrical connections of the flowmeter). The flowmeter is supplied with jumpers attached. The SONIX 10D flowmeter enables readings of temporary values of the flow Unit change and the content of counters in mass units (t/h, t and kg). In order to achieve...
  • Page 15: List Of Registers

    Instructions for Assembly and Operating SONIX 10D List of registers Register Variable Name of the variable type float LO Flow m3/h ( t/h) long int HI Positive volume m3(t) Positive volume l(kg) float Liquid speed m/s errors 1... 16 reserved...
  • Page 16: Declaration Of Conformity

    Instructions for Assembly and Operating SONIX 10D DECLARATION OF CONFORMITY The manufacturer: SONIX ® Industrial Electronic Devices ul. Leopolda Lisa-Kuli 12, 05-270 Marki declares that the following described product: Ultrasonic Flowmeter type SONIX10D is compliant with the requirements of the European Counsil directives no...
  • Page 17: Guarantee Certificate

    (e.g. the probes’ surface covering with deposit, presence of air in the pipeline, exceeding the allowed temperature limit for the ultrasound probes etc.). Name of the product: ULTRASOUND FLOWMETER, type: SONIX 10D Purchasing company:..................

Table of Contents