Troubleshooting - Greenlee 35346 Instruction Manual

Capstan retrofit kit for super tugger
Table of Contents

Advertisement

Troubleshooting

Should the puller become inoperative, refer to the troubleshooting table below. While performing any repairs,
inspect the motor, capstan, and drivetrain.
Problem
Motor will not run.
Capstan does not rotate while
motor is running.
Greenlee Tools, Inc.
6000-Series Super Tugger Cable Pullers
Probable Cause
No power at supply circuit.
Faulty switch or wiring.
Motor faulty.
#60 chain broken.
#40 chain broken.
Broken sprocket in gearbox or stripped
shaft in motor.
31
Probable Remedy
Check power supply with a voltmeter.
See the Specifications section of this
manual.
Check the switch and wiring for
continuity.
Check the motor and wiring for
continuity. Check condition of brushes.
Replace any worn or damaged items.
Replace motor.
Replace #60 chain.
Replace #40 chain.
Disassemble puller. See disassembly
instructions under Inspecting the
Chains and Ratchet Pawl. Replace
any worn or damaged drive
components.