Maintenance

Read all instructions thoroughly. Be sure that you
understand all of the instructions and have the
necessary tools available before dismantling the puller.
Service Activity
Lubricate the drive chains.
Grease the drive chain shafts.
Inspect the chains and ratchet pawl.
Inspect the commutator brushes.
Electric shock hazard:
Disconnect the cable puller from
the power supply before servicing.
Failure to observe this warning can
result in severe injury or death.
Greenlee Tools, Inc.
6000-Series Super Tugger Cable Pullers
Lubricating the Drive Chains (every 20 hours)
1. Remove the right outer guard (71) and left outer
guard (4).
2. Lubricate the inside of the chains with 80W-90W
Schedule
gear oil.
3. Replace the guards and screws.
every 20 hours
every 20 hours
Greasing the Drivetrain Shafts (every 20 hours)
every 40 hours
Apply a multipurpose NLGI Grade 2 grease (such as
Mobilgrease
every 40 hours
fittings (5 and 52). These fittings are located inside the
capstan housing and under the countershaft (47).
26
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
HP or Amoco Permalub) at the grease
®