F50E DUCT MOUNTED ELECTRONIC AIR CLEANER
SCREWS (2)
1
PROVIDED IN 136377A REMOTE MOUNT KIT.
Fig. 17. Mount the power box and the junction box
on the remote base.
Connect Cable to Air Cleaner Cabinet
Remove the screws holding the front of the contact tray
in place and lower the contact tray. Remove and discard
the two loose wires attached to the ionizer and
collector terminals.
Remove desired knockout from the top or back of the air
cleaner cabinet and install end of conduit assembly with
high voltage leadwire ends.
Connect the black wire to the collector terminal and the red
wire to the ionizer terminal. See Fig. 18.
Mount one of the quick-connect ground terminals and the
leaf spring supplied in the kit on the contact tray and
connect the white wire to it. See Fig. 18.
Replace the contact tray and secure with the two screws
removed earlier. Be careful not to pinch the wires between
the cabinet and tray.
Plug the hole in the top of the cabinet with the metal
plug provided.
Fasten the Cabinet to the Furnace
NOTE: This procedure shows a side installation on a typical
highboy furnace. You may need to alter the
procedure to fit your application.
68-0072—5
POWER
BOX)
REMOTE
MOUNTING
BASE
1
JUNCTION
BOX
SCREWS (2)
M6498
Align the cabinet with the return air opening.
Install a transition when the furnace and air cleaner
openings are different sizes. See Fig. 11.
Place blocks under the cabinet so the unit is firmly
supported and level. The 5/8 in. (16 mm) mounting foot on
the cabinet hinge plate provides the minimum clearance
required for the access door hinge.
Attach the cabinet securely to the furnace. The unit can be
attached directly, as shown, or a starting collar can first be
fitted in the furnace opening. Either drill holes and fasten
with sheetmetal screws or rivets, or use slip joints. If you
are drilling holes, locking pliers help to hold the unit in
place during drilling. See Fig. 20.
Install Turning Vanes
Mount turning vanes inside the elbow or angle fitting that is
directly against the air cleaner cabinet.
Fasten Cabinet To Ductwork
Install a transition when the opening in the air cleaner
cabinet and the duct are different sizes. See Fig. 11.
Fasten the other side of the cabinet to the elbow using
sheetmetal screws, rivets, or slip joints, as appropriate.
Install Optional W8600E Solid State
Performance Indicator
When the W8600E Solid State Performance Indicator is part
of the installation, install the W8600E in the desired location
and run 4-wire thermostat cable (up to 18 gauge),
independent of any other current-carrying wires, to the air
cleaner's power box as follows.
W8600E Location
The styling of the W8600E is designed to blend with the
Chronotherm III® Thermostats. A special mounting template
is included in the bag assembly for mounting next to the
thermostat. The W8600E Indicator can, however, be mounted
at any other convenient location in the living area, or it can be
mounted in the furnace room. It shares no electrical
connections with the thermostat.
Make certain the location makes it convenient for the
homeowner to observe the LEDs of the device.
Mounting W8600E
The following mounting instructions assume that the W8600E
will be mounted next to a Chronotherm III® Thermostat.
When installing the wall panel at another location, modify the
procedure to fit the installation.
Remove the cover from the W8600E.
Hold the mounting template (included in the W8600E bag
assembly) next to the thermostat as shown in Fig. 21.
Hold the base for the W8600E next to the template and
mark holes for screw anchors and access hole for 4-wire
thermostat cable from the terminal strip on the F50E
power box to the W8600E base.
Remove the W8600E base and drill the holes. Install the
anchors and screws so that the base is mounted firmly on
the wall at the correct distance from the thermostat.
10