Are you controlling the camera
with an ExSync signal or is the
camera in free-run?
ExSync signal.
Check the setup on your frame
grabber and make sure that the
ExSync signal is not too short. The
period of the ExSync signal must
be greater than 20.83 ms.
(On many frame grabbers, the
period of the ExSync signal is
adjusted by changing a setting for
the "frame rate". Your frame rate
should not exceed 48 fps.)
Is the ExSync period OK?
Yes
Check your exposure setting.
The exposure time must be
less than the ExSync period.
Is the exposure OK?
Yes
Switch on test image one.
Can the test image be seen?
Yes
Replace the camera.
BASLER A202
k
DRAFT
Free-run.
Correct
the
No
settings.
Correct
No
the
setting.
Go to the
interfacing
No
troubleshooting
chart.
Did you set up free-run using the Exposure Time Control Mode
setting on the CCT+ or with binary commands?
CCT+
Binary
Commands
Check to make sure that:
Timer 1 is set no lower than
13 µs.
Timer 2 is set no lower than
35 µs.
The sum of the Timer 1 setting
plus the Timer 2 setting is
greater than 20.83 ms.
Are the settings OK?
Yes
Switch on the test image one.
Can the test image be seen?
Yes
Replace the camera.
Troubleshooting
Correct
No
the
settings.
Go to the
interfacing
No
troubleshooting
chart.
6-3