Understanding the Signal Lights

The three lights (LEDs) on the front panel of the NT1 provide
information about the status of the NT1 and the ISDN line.
Table 2 explains the significance of each light.
Light
L-BK
LINE
PWR
L-BK
Figure 3. Signal Lights
State
Off
On
On
Flashes 8 times
Flashes once per second
Off
On
Off
Table 2. Explanation of the Signals
Eicon Network Termination (NT1) Installation Guide
LINE
PWR
Explanation
Normal.
Your ISDN service provider is
conducting a loopback test.
The S/T and U interfaces are not active.
The NT1 is trying to activate the
U-interface link.
The S/T interface is not fully active.
The S/T and U interfaces are fully active.
The power supply is connected.
The NT1 is not receiving power.