5. Before starting the equipment

Warning!
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines (ex-
tensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
The equipment must be set up where it can
stand securely.
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).

6. Assembly and starting

Notice!
You must fully assemble the appliance before
using it for the fi rst time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 3.
6.2 Fitting the supporting foot (4)
Fit the supplied rubber stopper as shown in Fig. 4.
Anl_TC_AC_200_24_8_OF_EX_UK_SPK7.indb 9
Anl_TC_AC_200_24_8_OF_EX_UK_SPK7.indb 9
GB
6.3 Voltage
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossib-
le.
6.4 On/Off switch (8)
To switch on the equipment, set the On/Off switch
(8) to position 1.
To switch off the equipment, move the On/Off
switch (8) to position 0.
6.5 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Warning!
After use, always switch off the equipment
immediately and pull out the power plug.