3. Use the directional keypad to configure
the fuel tank capacity.
Set using the [SET] button.
TIP:
• The fuel tank capacity must be configured
for each fuel tank.
• The displayed unit for the fuel tank capac-
ity can be changed. For details on how to
change the displayed unit, see "Setting the
displayed units (Units)" (page 32).
4. Select "Calibration". Set using the [SET]
button.
TIP:
• Multi Point Calibration uses 5 calibration
points and Single Point Calibration uses
only 1 calibration point.
• Select "Delete Calibration" to delete old
calibration data.
• It is not possible to proceed to "Calibration
Step 1" of "Multi Point Calibration" or "Sin-
gle Point Calibration" if any fuel remains in
the fuel tank.
5. With no fuel remaining in the fuel tank
(the fuel tank sensor should be posi-
tioned at the bottom of the fuel tank),
press the [SET] button.
6. A confirmation screen will appear. Press
the [SET] button to confirm.
TIP:
• The Single Point Calibration of the fuel
tank sensor is complete.
• In case of the Multi Point calibration, the
calibration data will be saved at each point.
Accordingly, the next time you perform a
calibration, it is possible to proceed with
the next point even if you abort the current
calibration process.