Download Print this page

Advertisement

Quick Links

DORMA
DORMA AUTOMATICS, Inc.
ESA II
ASP MANUAL
ESA II
ASP MANUAL
Distributed by:
924 Sherwood Drive
Lake Bluff, IL 60044
E-mail: automatics@dorma-usa.com
Toll-Free: 877-367-6211
Fax: 877-423-7999
Subject to change without notice
DL2843-010
Jan. 2007

Advertisement

loading
Need help?

Need help?

Do you have a question about the ESA II and is the answer not in the manual?

Questions and answers

Summary of Contents for Dorma ESA II

  • Page 1 DORMA ESA II ASP MANUAL ESA II ASP MANUAL Distributed by: DORMA AUTOMATICS, Inc. 924 Sherwood Drive Toll-Free: 877-367-6211 DL2843-010 Lake Bluff, IL 60044 Fax: 877-423-7999 Jan. 2007 E-mail: automatics@dorma-usa.com Subject to change without notice...
  • Page 2 DORMA ESA II ASP MANUAL Index General information Page 1 Con guration menu Page 2 Control parameter menu Page 2 - 3 Special function menu Page 3 - 4 Diagnostics menu Page 5 - 7 PDA, error and help text...
  • Page 3 DORMA ESA II ASP MANUAL Con guration menu: The con guration menu contains all the system-speci c parameters relating to the application concerned. These parameters are described in the following. locking device Integrated locking device No locking device none Bistable locking device...
  • Page 4: Special Function Menu

    DORMA ESA II ASP MANUAL part. open. width Partial opening width as factory setting. from 100 x 0,1 inch After learning cycle half opening width. 315 x 0,1 in with PDA only Partial opening width can only be adjusted using the PDA.
  • Page 5 DORMA ESA II ASP MANUAL battery mode Setting of the rechargeable battery pack mode of the basic module (BM). no battery emerg.-clos. emerg.-open. emerg.-mode airl. door status 1 The potential-free contact OUT 2 on the Function module (FM) none (Addr. 49) is closed when the door is in the CLOSED position (original door open setting).
  • Page 6: Diagnostics Menu

    DORMA ESA II ASP MANUAL Diagnostics menu: Meaning of symbols: Select Error Proceed Back Help software ver. GM Indication of the current BM (bas ic module) software version. The select i.e. 0100 = symbol calls up the rmware list. Select the rmware and activate the version 1.00...
  • Page 7 DORMA ESA II ASP MANUAL The framed data can be entered here and stored in the BM basic module using the "Upload” function. system no. Door/System number DORMA-prod.-no. DORMA Production Number installation date Date of installati last maintenance Last maintenance activi...
  • Page 8 DORMA ESA II ASP MANUAL external sensor Indicates external detector status. inactive active i t c active inactive PGS OFF Indicates PGS mode. active i t c active PGS EXIT ONLY Indicates PGS mode. inactive active PGS PART. i t c...
  • Page 9 DORMA ESA II ASP MANUAL PDA, error and help texts Characters in parentheses are shown in the 7-segment display of the basic module. control unit is error-free Contol unit is error-free door blocked (obstacle) Remove obstacle! Check oor guide! Adjust blocking sensor and force limitation!
  • Page 10: Troubleshooting

    In this case, the upload must be repeated. If the upload was successful, the LED is green. The PDA may also be used to install a new software version on the service key. Software upload from PDA to service key: See ESA II ASP data base recording.