Butler OVP-1224 User Manual

Electric oven & proofer

Advertisement

Quick Links

USER
MANUAL
Electric Oven & Proofer:
OVP-1224

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OVP-1224 and is the answer not in the manual?

Questions and answers

Summary of Contents for Butler OVP-1224

  • Page 1 USER MANUAL Electric Oven & Proofer: OVP-1224...
  • Page 2: Brief Introduction

    Range (℃) Capacity Temperature WxDxH (mm) (kg) Rising (min) OVP-1224 380V/ 50Hz 15.8 20~400 40 (kg/h) 1300x845x1845 Notices on Installation and Operation Environment 1. This device is for indoor operation only, which can be placed on the ground or on the top of a firm stand, and should be over 20 cm apart from the wall.
  • Page 3 Qty of Poles Current ≦I△n(mA) In(A) and Voltage OVP-1224 4poles-380V 3. The protection grade for electrical components that are reachable is Category1, wires in the two colors yellow and green are used for grounding, which should be securely connected with the grounding conductors conforming to relevant national regulations on marking secure use of electric power.
  • Page 4 User Manual 5. The waterproof grade of this baking oven is Generic Category, therefore, it is for indoor operation only. Placing the baking oven at a location with a spray of water or cleaning it with water jetting is strictly prohibited. 6.
  • Page 5: Electrical Principle Diagram

    User Manual Electrical Principle Diagram This drawing is for your reference only, and is subject to change without additional notice. Generic Breakdown and Remedy BREAKDOWN POSSIBLE CAUSE REMEDY The leakage current protection Leakage current from electric Find out the error component, switches trip off.
  • Page 6: Installation

    Production Weight Range (℃) Rating (kw) L×W×H(mm) Capacity (kg/h) (kg) OVP-1224 220V/50Hz 20~110 500×730×1610 Notes: 1. Production capacity is based on the output of bread. 2.All data are subject to change without notice. Installation 1. The series of machines should be used only in an indoor environment where the relative humidity is within the range of 45-85% and the temperature is higher than 5℃.
  • Page 7: Operation Procedure

    User Manual relevant national security regulations. Warning: The electric conductors are strictly prohibited to be connected with water supply pipes, natural gas pipes and caliducts, otherwise, security accidents would be induced. 4. An equal-potential connection screw is foreseen on the back area of the machine. In case that any other equipment inside the same room have equal-potential connections, the equal-potential connection screw of this machine should be connected to an equal- potential terminal of the other equipment through a copper conductor with a section area...
  • Page 8 User Manual machine, wipe and clean it with a piece of cloth soaked in neutral cleanser solution. After the dirt has been removed, wipe it with a piece of clean, wet cloth. The connection mode of the power supply circuit is of X type. In case of replacing the power supply wires, rubber sheath wires with specification similar to that of the wire type Yzw1.5mm that has been equipped for this machine must be adopted.