Controlling The Temperature; Programmable Function Parameters; Maintenance And Servicing - Franke PRTR0006 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3

12. Controlling the Temperature

Sink mixer
with mixing lever
12.1 Set the mixing lever (a) in the desired position.

13. Programmable Function Parameters

The optional remote control FAR Order No. 2000101087 offers the following
functions:
– Range can be set (3-20 cm)
– Turn-off delay can be set (0-10 s)
– Continuous flow can be switched to 3.5 min or 11 min.
– Switching off the fitting
– Basic settings can be restored
– Test mode for simulation without water
– Setting automatic safety switch-off (2–210 s)
– Automatic flushing can be activated
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. The range must be reduced for installations on reflecting surfaces such
as stainless steel washbasins. If this is not sufficient, an additional base/spacing ring
is available (see

14. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Aerators (see
• Filters (see
• Non-return valves (see
14.1 Push up the cleaning clip (a) in front of the sensor.
The fitting is in sleep mode.
14.2 Properly use suitable cleaning agents that are not harmful to the fittings and rinse
with water after use. High-pressure cleaners must not be used for cleaning.
Chapter
20.).
Chapter
15.)
Chapter
16.)
Chapter
info@hygiene-shop.eu - www.hygiene-shop.eu
17.)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

7612982184628

Table of Contents