5. Leak Testing:
IMPORTANT: Leak testing of the appliance shall be conducted as follows:
• After final gas connection is made, turn on manual gas valve and test all
connections in gas supply piping and appliance for gas leaks with a soapy water
solution. During this test all appliance gas valves have to be closed.
• In order to avoid property damage or serious personal injury , never use a Iighted
match. If a leak is present, tighten joint or unscrew, apply more joint compound,
tighten again and retest connection for leak.
CONVERSION TO LP/PROPANE GAS
Every oven is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the "INJECTORS TABLE".
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
SETTING THE PRESSURE REGULATOR
1. Unscrew the regulator cover;
2. Unscrew the A component, reverse and screw it according to the LP/PROPANE
regulation.
LP/PROPANE
REGULATION
INJECTORS TABLE
NOMINAL
POWER
BTU/hr
BURNERS
Oven burner
11000
Broil burner
7000
NATURAL GAS
REGULATION
REDUCED
LP/PROPANE
POWER
11" W.C.P.
Ø injector
By-pass
BTU/hr
[1/100 mm]
[1/100 mm]
1500
96
34
–
78
A
NATURAL GAS
4" W.C.P.
Ø injector
By-pass
[1/100 mm]
[1/100 mm]
164
adjustable
–
130
–
1
2
Fig. 6.5
23