Dell PowerEdge 6850 Information Update page 12

Dell poweredge 6850 servers: supplementary guide
Hide thumbs Also See for PowerEdge 6850:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table 1-2. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E0880
PS REDUNDANCY
LOST
BP DRIVE n
E0D76
E0D76
SCSI CONNECTOR
EB107
PROC BUS PERR
PROC INIT ERR
PROC PROTOCOL
ERR
PROC MACHINE CHK Faulty or improperly installed
EB107
EB107
PROC HOT
EB10C
ECC UNCORR ERR
ECC UNCORR ERR
BANK #
10
Information Update
Causes
Power supply redundancy has
been lost because a power supply
has been removed from the
system.
Faulty or improperly installed
hard drive or RAID controller.
SCSI cable is not connected.
Faulty or improperly installed
microprocessor or system board.
microprocessor or system board.
Processor is out of acceptable
temperature range and has halted
operation.
Uncorrectable ECC errors have
occurred in system memory. The
affected memory bank may be
specified.
Corrective Actions
Reinstall the power supply to
restore redundancy.
See "Troubleshooting SCSI Hard
Drives," "Troubleshooting a RAID
Controller Card," and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting SCSI Hard
Drives" in your Installation
and Troubleshooting Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Memory" in your Installation
and Troubleshooting Guide.

Advertisement

Table of Contents
loading

Table of Contents